Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations

被引:128
作者
Wang, Y
Vaidya, B
Farquar, HD
Stryjewski, W
Hammer, RP
McCarley, RL
Soper, SA [1 ]
Cheng, YW
Barany, F
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[2] Cornell Univ, Joan & Sanford I Weill Med Coll, Dept Microbiol, New York, NY 10021 USA
关键词
D O I
10.1021/ac020683w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-density arrays were assembled into microfluidic channels hot-embossed in poly(methyl methacrylate) (PMMA) to allow the detection of low-abundant mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. Following spotting, the chip was assembled with a cover plate and the array accessed using microfluidics in order to enhance the kinetics associated with hybridization. The array was configured with zip code sequences (24-mers) that were complementary to sequences present on the target. The hybridization targets were generated using an allele-specific ligase detection reaction (LDR), in which two primers (discriminating primer that carriers the complement base to the mutation being interrogated and a common primer) that flank the point mutation and were ligated joined together) only when the particular mutation was present in the genomic DNA. The discriminating primer contained on its 5'-end the zip code complement (directs the LDR product to the appropriate site of the array), and the common primer carried on its 3' end a fluorescent dye (near-IR dye IRD-800). The coupling chemistry (5'-amine-containing oligonucleotide tethered to PMMA surface) was optimized to maximize the loading level of the zip code oligonucleotide, improve hybridization sensitivity (detection of low-abundant mutant DNAs in high copy numbers of normal sequences), and increase the stability of the linkage chemistry to permit re-interrogation of the array. It was found that microfluidic addressing of the array reduced the hybridization time from 3 h for a conventional array to less than 1 min. In addition, the coupling chemistry allowed reuse of the array > 12 times before noticing significant loss of hybridization signal. The array was used to detect a point mutation in a K-ras oncogene at a level of 1 mutant DNA in 10 000 wild-type sequences.
引用
收藏
页码:1130 / 1140
页数:11
相关论文
共 63 条
  • [51] Molecular interactions on microarrays
    Southern, E
    Mir, K
    Shchepinov, M
    [J]. NATURE GENETICS, 1999, 21 (Suppl 1) : 5 - 9
  • [52] Stellwagen NC, 2001, BIOPOLYMERS, V58, P390, DOI 10.1002/1097-0282(20010405)58:4<390::AID-BIP1015>3.0.CO
  • [53] 2-K
  • [54] Tawata M, 2000, COMB CHEM HIGH T SCR, V3, P1
  • [55] Biochemical properties of a high fidelity DNA ligase from Thermus species AK16D
    Tong, J
    Cao, WG
    Barany, F
    [J]. NUCLEIC ACIDS RESEARCH, 1999, 27 (03) : 788 - 794
  • [56] Wabuyele MB, 2001, ELECTROPHORESIS, V22, P3939, DOI 10.1002/1522-2683(200110)22:18<3939::AID-ELPS3939>3.0.CO
  • [57] 2-9
  • [58] High-resolution near-infrared imaging of DNA microarrays with time-resolved acquisition of fluorescence lifetimes
    Waddell, E
    Wang, Y
    Stryjewski, W
    McWhorter, S
    Henry, AC
    Evans, D
    McCarley, RL
    Soper, SA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (24) : 5907 - 5917
  • [59] WEI Q, 1992, MOL BIOL CELL, V3, pA22
  • [60] WIEDMANN M, 1994, PCR METH APPL, V3, pS51