Hard X-ray phase imaging and tomography with a grating interferometer

被引:27
作者
Weitkamp, T [1 ]
Diaz, A [1 ]
Nöhammer, B [1 ]
Pfeiffer, F [1 ]
Rohbeck, T [1 ]
Cloetens, P [1 ]
Stampanoni, M [1 ]
David, C [1 ]
机构
[1] Paul Scherrer Inst, Lab Micro & Nanotechnol, CH-5232 Villigen, Switzerland
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY IV | 2004年 / 5535卷
关键词
X-ray tomography; phase-stepping interferometry; synchrotron radiation; microtomography; phase reconstruction;
D O I
10.1117/12.569643
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a two-grating interferometer for hard X rays that can be used for phase imaging and tomography. A silicon phase grating positioned just downstream of the object under study splits the distorted wavefront into essentially a positive and a negative first-order beam. At a given distance from this beam-splitter grating, where the two beams still mostly overlap, they form a pattern of interference fringes that is distorted according to the wavefront distortions. The fringes may be finer than the resolution of an area detector used to record the signal, but an absorption grating with suitable pitch. put in front of the detection plane, allows the detection of intensity variations that correspond to the derivative of ne wavefront phase taken along the direction perpendicular to the grating lines. A combination of this technique with the phase-stepping method, in which several exposures are made which differ in the phase of the fringe pattern, allows to eliminate effects of non-uniform intensity due to inhomogeneous illumination and edge-enhancing inline phase contrast. Several examples of tomograms taken under different experimental conditions are shown, including a polychromatic "pink-team'' setup.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 15 条
[1]   X-ray microtomography (mu CT) using phase contrast for the investigation of organic matter [J].
Beckmann, F ;
Bonse, U ;
Busch, F ;
Gunnewig, O .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :539-553
[2]   AN X-RAY INTERFEROMETER [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 6 (08) :155-&
[3]   Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays [J].
Cloetens, P ;
Ludwig, W ;
Baruchel, J ;
Van Dyck, D ;
Van Landuyt, J ;
Guigay, JP ;
Schlenker, M .
APPLIED PHYSICS LETTERS, 1999, 75 (19) :2912-2914
[4]   Phase objects in synchrotron radiation hard x-ray imaging [J].
Cloetens, P ;
Barrett, R ;
Baruchel, J ;
Guigay, JP ;
Schlenker, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) :133-146
[5]  
Creath K., 1988, Progress in optics. Vol.XXVI, P349, DOI 10.1016/S0079-6638(08)70178-1
[6]   Differential x-ray phase contrast imaging using a shearing interferometer [J].
David, C ;
Nöhammer, B ;
Solak, HH ;
Ziegler, E .
APPLIED PHYSICS LETTERS, 2002, 81 (17) :3287-3289
[7]  
DILMANIAN FA, 2000, PHYS MED BIOL
[8]   Phase-sensitive x-ray imaging [J].
Fitzgerald, R .
PHYSICS TODAY, 2000, 53 (07) :23-26
[9]  
Ingal V N, 1995, J PHYS D
[10]   Phase-sensitive imaging and phase tomography using X-ray interferometers [J].
Momose, A .
OPTICS EXPRESS, 2003, 11 (19) :2303-2314