Analysis of antigen-specific antibodies and their isotypes in experimental malaria

被引:12
作者
van der Heyde, Henri C.
Burns, James M.
Weidanz, William P.
Horn, Jolm
Gramaglia, Irene
Nolan, John P.
机构
[1] La Jolla Bioengn Inst, La Jolla, CA 92037 USA
[2] Drexel Univ, Dept Microbiol & Immunol, Philadelphia, PA 19129 USA
[3] Univ Wisconsin, Dept Microbiol & Immunol, Madison, WI 53706 USA
关键词
immune response; Plasmodium; AMA1; MSP1; affinity;
D O I
10.1002/cyto.a.20377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Measuring antibody production in response to antigen exposure or vaccination is key to disease prevention and treatment. Our understanding of the mechanisms involved in the antibody response is limited by a lack of sensitive analysis methods. We address this limitation using multiplexed microsphere arrays for the semi-quantitative analysis of antibody production in response to malaria infection. Methods: We used microspheres as solid supports on which to capture and analyze circulating antibodies. Antigen immobilized on beads captured antigen-specific antibodies for semi-quantitative analysis using fluorescent secondary antibodies. Anti-immunoglobulin antibodies on beads captured specific antibody isotypes for affinity estimation using fluorescent antigen. Results: Antigen-mediated capture of plasma antibodies enables determination of antigen-specific antibody "titer," a semi-quantitative parameter describing a convolution of antibody abundance and avidity, as well as parameters describing numbers of antibodies bound/bead at saturation and the plasma concentration-dependent approach to saturation. Results were identical in single-plex and multiplex assays, and in qualitative agreement with similar parameters derived from ELISA-based assays. Isotype-specific antibody-mediated capture of plasma antibodies allowed the estimation of the affinity of antibody for antigen. Conclusion: Analysis of antibody responses using microspheres and flow cytometry offer significant advantages in speed, sample size, and quantification over standard ELISA-based titer methods. (c) 2007 international Society for Analytical Cytology.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 17 条
[11]   Analysis of the HIV-1 gp41 specific immune response using a multiplexed antibody detection assay [J].
Opalka, D ;
Pessi, A ;
Bianchi, E ;
Ciliberto, G ;
Schleif, W ;
McElhaugh, M ;
Danzeisen, R ;
Geleziunas, R ;
Miller, M ;
Eckert, DM ;
Bramhill, D ;
Joyce, J ;
Cook, J ;
Magilton, W ;
Shiver, J ;
Emini, E ;
Esser, MT .
JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 287 (1-2) :49-65
[12]   Simultaneous quantitation of antibodies to neutralizing epitopes on virus-like particles for human papillomavirus types 6, 11, 16, and 18 by a multiplexed luminex assay 2 [J].
Opalka, D ;
Lachman, CE ;
MacMullen, SA ;
Jansen, KU ;
Smith, JF ;
Chirmule, N ;
Esser, MT .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) :108-115
[13]  
Ruiz Wanda, 2005, J Immune Based Ther Vaccines, V3, P2, DOI 10.1186/1476-8518-3-2
[14]   Mass value assignment of total and subclass immunoglobulin G in a human standard anthrax reference serum [J].
Semenova, VA ;
Steward-Clark, E ;
Stamey, KL ;
Taylor, TH ;
Schmidt, DS ;
Martin, SK ;
Marano, N ;
Quinn, CP .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (05) :919-923
[15]  
Snow RW, 2005, NATURE, V434, P214, DOI 10.1038/nature03342
[16]  
VANDERHEYDE HC, 1994, J IMMUNOL, V152, P4557
[17]  
vonderWeid T, 1996, J IMMUNOL, V156, P2510