Hydroxyapatite implant wrapping materials: Analysis of fibrovascular ingrowth in an animal model

被引:20
作者
Klapper, SR [1 ]
Jordan, DR [1 ]
Punja, K [1 ]
Brownstein, S [1 ]
Gilberg, SM [1 ]
Mawn, LA [1 ]
Grahovac, SZ [1 ]
机构
[1] Ophthalmol Consultants Ft Wayne PC, Ft Wayne, IN USA
关键词
D O I
10.1097/00002341-200007000-00005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the influence of seven currently available spherical orbital implant wraps on host fibrovascularization of a hydroxyapatite (HA) orbital implant. Methods: Five groups of 3 (15 total) adult male New Zealand albino rabbits underwent enucleation with placement of a 12-mm HA implant wrapped in high-porosity expanded polytetrafluoroethylene (e-PTFE), processed bovine pericardium, or processed human pericardium, sclera, or fascia lata. Magnetic resonance imaging before and after the intravenous administration of gadolinium-diethylenetriamine pentaacetic acid (DTPA, 0.1 mol/kg) was performed immediately before exenteration. Five rabbits tone with each of the different implant wraps) were killed at 4, 8, and 12, weeks, and the operated socket was exenterated. Histopathologic sections of the implants were then compared with the results of our previous study using polyglactin 910 mesh and autologous sclera as HA orbital implant wraps. Results: Complete fibrovascularization of all the implants occurred by 12 weeks; however, HA implants wrapped with sclera, polyglactin mesh, and e-PTFE appeared to undergo more rapid fibrovascularization than spheres wrapped with other materials. Conclusions: Although all of the implant wraps studied may be suitable substitutes for donor sclera, we prefer polyglactin mesh because it is readily available, inexpensive, and without risk of transmissible diseases.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 50 条
[31]  
KOHLER TR, 1992, SURGERY, V112, P901
[32]   A NEW FLUOROCARBON FOR KERATOPROSTHESIS [J].
LEGEAIS, JM ;
ROSSI, C ;
RENARD, G ;
SALVOLDELLI, M ;
DHERMIES, F ;
POULIQUEN, YJ .
CORNEA, 1992, 11 (06) :538-545
[33]   POLYTEF (POLYTETRAFLUOROETHYLENE) ALLOPLASTIC GRAFTING AS A SUBSTITUTE FOR MUCOUS-MEMBRANE [J].
LEVIN, PS ;
DUTTON, JJ .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (02) :282-285
[34]  
Lusky M, 1992, J Glaucoma, V1, P221, DOI 10.1097/00061198-199201040-00001
[35]   VICRYL (POLYGLACTIN-910) MESH AS A DURAL SUBSTITUTE [J].
MAURER, PK ;
MCDONALD, JV .
JOURNAL OF NEUROSURGERY, 1985, 63 (03) :448-452
[36]   USE OF VICRYL (POLYGLACTIN-910) MESH IMPLANT FOR CORRECTING ENOPHTHALMOS AND HYPOOPHTHALMOS - A STUDY OF 16 PATIENTS [J].
MAURIELLO, JA ;
MCSHANE, R ;
VOGLINO, J .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 6 (04) :247-251
[37]   Wrapping hydroxyapatite orbital implants with posterior auricular muscle complex grafts [J].
Naugle, TC ;
Lee, AM ;
Haik, BG ;
Callahan, MA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (04) :495-501
[38]   High leg incision fascia lata harvesting [J].
Naugle, TC ;
Fry, CL ;
Sabatier, RE ;
Elliott, LF .
OPHTHALMOLOGY, 1997, 104 (09) :1480-1488
[39]   Complications of hydroxyapatite orbital implants - A review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping [J].
Oestreicher, JH ;
Liu, E ;
Berkowitz, M .
OPHTHALMOLOGY, 1997, 104 (02) :324-329
[40]   Clinicopathological correlation of technetium bone scan in vascularization of hydroxyapatite implants - A primate model [J].
Pacheco, EM ;
Civelek, AC ;
Natarajan, TK ;
DAnna, SA ;
Iliff, NT ;
Green, WR .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (09) :1173-1177