摘要
Purpose of review The increasing numbers of patients on oral anticoagulants may challenge the traditional organization of patient monitoring. The availability of portable coagulometers capable of measuring prothrombin time (PT) international normalized ratio (INR) in a drop of capillary blood facilitates decentralization of monitoring by self-testing. This article reviews the literature on use of portable coagulometers. Recent findings Numerous studies have evaluated the reliability of portable coagulometers in testing the PT-INR. This has been assessed by statistically as well as clinically relevant criteria. Other studies have been devoted to developing calibration models fulfilling the criteria recommended by the World Health Organization (WHO) for the calibration of INR measuring systems. Finally, studies have assessed the value of schemes for patient training and for the long-term quality assurance of portable coagulometers. Summary It can be concluded from the published studies that PT-INR self-testing may be considered as a suitable alternative to conventional laboratory testing. For the PT-INR to be reliable, manufacturers of portable coagulometers should calibrate their devices against international standards for thromboplastin with procedures similar to those recommended by WHO for conventional measuring systems. Training of patients and implementation of appropriate quality assessment schemes are also essential prerequisites for the success of PT-INR self-testing.
引用
收藏
页码:141 / 145
页数:5
相关论文
共 32 条
[1]  
BUTT H. R., 1941, PROC STAFF MEET MAYO CLINIC, V16, P388
[2]  
Cheung Dorothy S, 2003, Am J Geriatr Cardiol, V12, P283, DOI 10.1111/j.1076-7460.2003.02053.x
[3]  
Cosmi B, 2000, HAEMATOLOGICA, V85, P826
[4]   Accuracy of a portable prothrombin time monitor (Coagucheck) in patients on chronic oral anticoagulant therapy: A prospective multicenter study [J].
Cosmi, B ;
Palareti, G ;
Moia, M ;
Carpenedo, M ;
Pengo, V ;
Biasiolo, A ;
Rampazzo, P ;
Morstabilini, G ;
Testa, S .
THROMBOSIS RESEARCH, 2000, 100 (04) :279-286
[5]   Oral anticoagulation self-management and management by a specialist anticoagulation clinic:: a randomised cross-over comparison [J].
Cromheecke, ME ;
Levi, M ;
Colly, LP ;
de Mol, BJM ;
Prins, MH ;
Hutten, BA ;
Mak, R ;
Keyzers, KCJ ;
Büller, HR .
LANCET, 2000, 356 (9224) :97-102
[6]   Capillary whole blood testing by a new portable monitor - Comparison with standard determination of the international normalized ratio [J].
de Miguel, D ;
Burgaleta, C ;
Reyes, E ;
Pascual, T .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (01) :28-33
[7]   Accuracy of a portable international normalization ratio monitor in outpatients receiving long-term oral anticoagulant therapy: Comparison with a laboratory reference standard using clinically relevant criteria for agreement [J].
Douketis, JD ;
Lane, A ;
Milne, J ;
Ginsberg, JS .
THROMBOSIS RESEARCH, 1998, 92 (01) :11-17
[8]   Comparison of the quality of oral anticoagulant therapy through patient self-management and management by specialized anticoagulation clinics in the Netherlands - A randomized clinical trial [J].
Gadisseur, APA ;
Breukink-Engbers, WGM ;
van der Meer, FJM ;
van den Besselaar, AMH ;
Sturk, A ;
Rosendaal, FR .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (21) :2639-2646
[9]   Oral anticoagulants: Mechanism of action, clinical effectiveness, and optimal therapeutic range [J].
Hirsh, J ;
Dalen, JE ;
Anderson, DR ;
Poller, L ;
Bussey, H ;
Ansell, J ;
Deykin, D .
CHEST, 2001, 119 (01) :8S-21S
[10]  
KIRKWOOD TBL, 1983, THROMB HAEMOSTASIS, V49, P238