Cathodic electrochemical detection of nitrophenols at a bismuth film electrode for use in flow analysis

被引:103
作者
Hutton, EA
Ogorevc, B
Smyth, MR
机构
[1] Natl Inst Chem, Analyt Chem Lab, SI-1001 Ljubljana, Slovenia
[2] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
关键词
bismuth film electrode; nitrophenol; cathodic reduction; electrochemical detection; voltammetry; amperometry;
D O I
10.1002/elan.200402979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The bismuth film electrode (BiFE) is presented for use in both batch voltammetric and flow injection (FI) amperometric detection of some nitrophenols (2-nitrophenol, 2-NP; 4-nitrophenol, 4-NP; 2,4-dinitrophenol, 2,4-DNP). The bismuth film was deposited ex situ (batch measurements) and in-line (FI) onto a glassy carbon substrate electrode. Batch analysis of the nitrophenols was carried out in 0.04 M Britton Robinson (BR) buffer pH 4, while for FI measurements, a carrier/electrolyte solution composed of 0.1 M BR buffer pH 4 mixed with methanol (20 + 80, v/v%) was employed to resemble media used in preconcentration/clean-up and flow separation sample pretreatment procedures. Under batch conditions, the voltammetric behavior of the nitrophenols was examined for dependence on medium pH in the range of 2 to 10. Employing the square-wave voltammetry mode, the limits of detection were 0.4 mug L-1, 1.4 mug L-1, and 3.3 mug L-1 for 2-NP, 4-NP, and 2,4-DNP, respectively. Under flow conditions, a simple in-line electrochemical bismuth film renewal procedure was tested and shown to provide very good inter- and intra-electrode reproducibility of the current signals at low mug L-1 analyte concentrations. The limits of detection for 2-NP, 4-NP and 2,4-DNP obtained using FI and amperometric detection at -1.0 V (vs. Ag/AgCl) were 0.3 mug L-1, 0.6 mug L-1 and 0.7 mug L-1, respectively, with linear ranges extending up to 20 mug L-1. The attractive performance of the BiFE under flow analysis conditions offers great promise with respect to its detection capability and to its use for a prolonged period of time with no need for inconvenient removal of the electrode from the system for mechanical surface treatment.
引用
收藏
页码:1616 / 1621
页数:6
相关论文
共 40 条
[1]   DETERMINATION OF 2-NITROPHENOL, 4-NITROPHENOL, 2-METHOXY-5-NITROPHENOL, AND 2,4-DINITROPHENOL BY DIFFERENTIAL-PULSE VOLTAMMETRY AND ADSORPTIVE STRIPPING VOLTAMMETRY [J].
BAREK, J ;
EBERTOVA, H ;
MEJSTRIK, V ;
ZIMA, J .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1994, 59 (08) :1761-1771
[2]  
Bond A. M., 1980, MODERN POLAROGRAPHIC, pp. 195
[3]  
Browne J. T., 1979, POLAROGRAPHY MOL BIO, P111
[4]   Determination of total phenols in waters and wastewaters using flow injection with electrochemical detection; An alternative to the standard colorimetric procedure [J].
Christophersen, MJ ;
Cardwell, TJ .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :39-46
[5]  
Cordero-Rando MD, 1999, MIKROCHIM ACTA, V132, P7
[6]   COMPARATIVE VOLTAMMETRIC STUDY OF 2,4-DINITROPHENOL (DNP), ALBUMIN AND DNP-ALBUMIN AS AN ANALYTICAL APPROACH TO THE USE OF DNP AS A UNIVERSAL LABEL IN IMMUNOELECTROCHEMICAL ASSAYS [J].
COSTAGARCIA, A ;
FERNANDEZABEDUL, MT ;
TUNONBLANCO, P .
TALANTA, 1994, 41 (07) :1191-1200
[7]  
DOJLIDO JR, 1993, E HORWOOD SERIES WAT, P301
[8]  
GERHARTZ W, 1985, ULLMANS ENCY IND CHE, P187
[9]   Enrichment of nitrophenols in water by off- and on-column concentration for capillary electrophoresis [J].
He, Y ;
Lee, HK .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (05) :725-739
[10]   A CONTRIBUTION TO THE STUDY OF THE ELECTROCHEMICAL REDUCTION OF ORTHO-NITROPHENOL ON A MERCURY-ELECTRODE [J].
HERAS, AM ;
AVILA, JL ;
GARCIABLANCO, F .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 170 (1-2) :353-356