Determination of lead in wine by hydride generation atomic fluorescence spectrometry in the presence of hexacyanoferrate(III)

被引:33
作者
Karadjova, Irina B.
Lampugnani, Leonardo
D'Ulivo, Alessandro
Onor, Massimo
Tsalev, Dimiter L.
机构
[1] Univ Sofia, Fac Chem, Sofia 1164, Bulgaria
[2] CNR, Ist Proc Chim Fis, I-56124 Pisa, Italy
关键词
lead; wine; hydride generation atomic fluorescence spectrometry; hexacyanoferrate (III);
D O I
10.1007/s00216-007-1127-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L-1 HCl and 1% m/v K-3[Fe(CN)(6)] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 mu g L-1 and 1 mu g L-1, respectively. The relative standard deviation varies between 2-6% (within-run) and 4-11% (between-run) at 3-30 mu g L-1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2-25.8 mu g L-1 Pb.
引用
收藏
页码:801 / 807
页数:7
相关论文
共 45 条
[1]   DETERMINATION OF LEAD AND ALUMINUM IN PORT WINE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ALMEIDA, AA ;
BASTOS, ML ;
CARDOSO, MI ;
FERREIRA, MA ;
LIMA, JLFC ;
SOARES, ME .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1281-1285
[2]   Advantages and limitations of the semi-quantitative operation mode of an inductively coupled plasma-mass spectrometer for multi-element analysis of wines [J].
Almeida, CM ;
Teresa, M ;
Vasconcelos, SD .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :165-175
[3]  
Almeida CMR, 1999, ANAL CHIM ACTA, V396, P45
[4]   UV-irradiation and MW-digestion pre-treatment of Port wine suitable for the determination of lead isotope ratios by inductively coupled plasma mass spectrometry [J].
Almeida, CMR ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1815-1821
[5]  
Alonso EV, 1998, QUIM ANAL, V17, P167
[6]   Measurement of lead isotope ratios in wine by ICP-MS and its applications to the determination of lead concentration by isotope dilution [J].
Augagneur, S ;
Medina, B ;
Grousset, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1149-1152
[7]   Pb and Cu speciation and bioavailability in port wine [J].
Azenha, MAGO ;
Vasconcelos, MTSD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (11) :5740-5749
[8]   APPLICATION OF HYDRIDE GENERATION TO ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS OF WINES AND BEVERAGES - A REVIEW [J].
BALUJASANTOS, C ;
GONZALEZPORTAL, A .
TALANTA, 1992, 39 (04) :329-339
[9]   Evaluation of the accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector magnetic sector and time-of-flight analyzers [J].
Barbaste, M ;
Halicz, L ;
Galy, A ;
Medina, B ;
Emteborg, H ;
Adams, FC ;
Lobinski, R .
TALANTA, 2001, 54 (02) :307-317
[10]   DETERMINATION OF LEAD AND ARSENIC IN WINES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUNO, SNF ;
CAMPOS, RC ;
CURTIUS, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :341-344