Quantification of atrial tachyarrhythmia burden with an Implantable pacemaker before and after pulmonary vein isolation

被引:30
作者
Pürerfellner, H
Aichinger, J
Martinek, M
Nesser, HJ
Ziegler, P
Koehler, J
Warman, E
Hettrick, D
机构
[1] St Elisabeths Acad Teaching Hosp, Dept Cardiol, Linz, Austria
[2] Medtronic Inc, Minneapolis, MN USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 09期
关键词
atrial fibrillation; quality-of-life; pulmonary veins; ablation;
D O I
10.1111/j.1540-8159.2004.00620.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Long-term efficacy of pulmonary vein (PV) ostial isolation for paroxysmal atrial fibrillation is difficult to assess. We evaluated the net duration of atrial tachyarrhythmia episodes (burden), atrial tachyorrhythmia episode frequency, and quality-of-life (QOL) before and after PV isolation in patients with an existing pacemaker featuring extensive diagnostic capabilities. Due to frequent recurrences of paroxysmal atrial fibrillation, PV isolation was performed 21 +/- 10 months following pacemaker implantation on 12 patients (57 +/- 5 years) with normal left ventricular function. Atrial tachyarrhythmia burden (ATB) and episode frequency were monitored daily by the device both pre- and postablation. QOL questionnaires were collected at ablation and 1, 3, and 6 months thereafter. Patients were followed for 20 +/- 9 and 11 +/- 9 months pre- and postablation, respectively. Membrane-active antiarrhythmic medications were discontinued after ablation in 8 of 12 patients. PV isolation resulted in a significant reduction of ATB from a median of 3.2 hours/day (preablation) to 0.2 hours/day (postablation, P < 0.01, Wilcoxon signed-rank test). The median tachyarrhythmia frequency was 6.4 episodes/day (preablation) and 0.3 episodes/day (postablation, P = 0.09). QOL measures significantly improved over the data collection intervals (P < 0.05). Tachyarrhythmia burden was positively associated with Symptom Checklist frequency and severity (P < 0.01). Significant long-term reductions in total ATB (symptomatic and asymptomotic) were observed. Furthermore, reductions in ATB were associated with improvements in QOL measures. Extensive monitoring capabilities in implantable devices help provide complete disclosure on the effect of PV isolation in paroxysmal atrial fibrillation patients.
引用
收藏
页码:1277 / 1283
页数:7
相关论文
共 15 条
[1]   Effect of radiofrequency catheter ablation an health-related quality of life and activities of daily living in patients with recurrent arrhythmias [J].
Bubien, RS ;
KnottsDolson, SM ;
Plumb, VJ ;
Kay, GN .
CIRCULATION, 1996, 94 (07) :1585-1591
[2]   Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation [J].
Chen, SA ;
Hsieh, MH ;
Tai, CT ;
Tsai, CF ;
Prakash, VS ;
Yu, WC ;
Hsu, TL ;
Ding, YA ;
Chang, MS .
CIRCULATION, 1999, 100 (18) :1879-1886
[3]   The impairment of health-related quality of life in patients with intermittent atrial fibrillation: Implications for the assessment of investigational therapy [J].
Dorian, P ;
Jung, W ;
Newman, D ;
Paquette, M ;
Wood, K ;
Ayers, GM ;
Camm, J ;
Akhtar, M ;
Luderitz, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1303-1309
[4]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[5]   Pace-termination and pacing for prevention of atrial tachyarrhythmias:: Results from a multicenter study with an implantable device for atrial therapy [J].
Israel, CW ;
Hügl, B ;
Unterberg, C ;
Lawo, T ;
Kennis, I ;
Hettrick, D ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (10) :1121-1128
[6]   Long-term risk of recurrent atrial fibrillation as documented by an Implantable monitoring device -: Implications for optimal patient care [J].
Israel, CW ;
Grönefeld, G ;
Ehrlich, JR ;
Li, YG ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (01) :47-52
[7]   Delayed cure despite early recurrence after pulmonary vein isolation for atrial fibrillation [J].
O'Donnell, D ;
Furniss, SS ;
Dunuwille, A ;
Bourke, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (01) :83-+
[8]   Catheter ablation for paroxysmal atrial fibrillation - Segmental pulmonary vein ostial ablation versus left atrial ablation [J].
Oral, H ;
Scharf, C ;
Chugh, A ;
Hall, B ;
Cheung, P ;
Good, E ;
Veerareddy, S ;
Pelosi, F ;
Morady, F .
CIRCULATION, 2003, 108 (19) :2355-2360
[9]  
Pappone C, 2000, CIRCULATION, V102, P2619
[10]  
Rose MS, 1999, STAT MED, V18, P139, DOI 10.1002/(SICI)1097-0258(19990130)18:2<139::AID-SIM9>3.3.CO