Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography

被引:247
作者
Seneterre, E
Taourel, P
Bouvier, Y
Pradel, J
VanBeers, B
Daures, JP
Pringot, J
Mathieu, D
Bruel, JM
机构
[1] HOP ST LUC,DEPT RADIOL & MED IMAGING,BRUSSELS,BELGIUM
[2] HOP G DOUMERGUE,DEPT MED INFORMAT,F-30000 NIMES,FRANCE
[3] HOP HENRI MONDOR,DEPT MED IMAGING,F-94010 CRETEIL,FRANCE
关键词
computed tomography (CT); comparative studies; iron; liver neoplasms; CT; MR; magnetic resonance (MR); contrast enhancement; portography;
D O I
10.1148/radiology.200.3.8756932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare the diagnostic accuracy of computed tomography (CT) during arterial portography (CTAP) with that of unenhanced and ferumoxides-enhanced magnetic resonance (MR) imaging at 0.5 T in the detection of hepatic metastases. MATERIALS AND METHODS: Four pairs of radiologists independently assessed the metastatic involvement of 134 hepatic segments (31 with and 103 without metastasis) in 17 patients at unenhanced and ferumoxides-enhanced spin-echo and gradient-echo MR imaging (alone and in combination) and at CTAP. The diagnostic performance of the various imaging modalities was assessed by means of receiver operating characteristic analysis. RESULTS: The accuracy of CTAP, unenhanced MR imaging (combined unenhanced sequences), and ferumoxides-enhanced MR imaging (combined contrast material-enhanced sequences) was 0.925, 0.908, and 0.951, respectively. Ferumoxides-enhanced MR imaging was significantly more accurate (P < .05) than unenhanced MR imaging and CTAP. When 14 segments containing cysts were excluded, the difference between ferumoxides-enhanced MR imaging and CTAP was no longer statistically significant (P = .1). CONCLUSION: Ferumoxides-enhanced MR imaging is more accurate than unenhanced MR imaging and at least as accurate as CTAP for the detection of hepatic metastases.
引用
收藏
页码:785 / 792
页数:8
相关论文
共 38 条
[1]   ASSESSMENT OF RADIOLOGIC TESTS - CONTROL OF BIAS AND OTHER DESIGN CONSIDERATIONS [J].
BEGG, CB ;
MCNEIL, BJ .
RADIOLOGY, 1988, 167 (02) :565-569
[2]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[3]  
BRUEL JM, 1993, RADIOLOGY, V189, P273
[4]   DETECTION OF COLORECTAL LIVER METASTASES USING INTRAOPERATIVE ULTRASONOGRAPHY [J].
CHARNLEY, RM ;
MORRIS, DL ;
DENNISON, AR ;
AMAR, SS ;
HARDCASTLE, JD .
BRITISH JOURNAL OF SURGERY, 1991, 78 (01) :45-48
[5]  
Couinaud C., 1957, FOIE ETUDES ANATOMIQ
[6]   MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION [J].
DELANGE, EE ;
MUGLER, JP ;
BOSWORTH, JE ;
DEANGELIS, GA ;
GAY, SB ;
HURT, NS ;
BERR, SS ;
ROSENBLATT, JM ;
MERICKEL, LW ;
HARRIS, EK .
RADIOLOGY, 1994, 190 (03) :727-736
[7]  
DENYS A, 1994, RADIOLOGY, V193, P663
[8]   AN AMERICANS GUIDE TO COUINAUD NUMBERING SYSTEM [J].
DODD, GD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (03) :574-575
[9]   DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS [J].
EDELMAN, RR ;
SIEGEL, JB ;
SINGER, A ;
DUPUIS, K ;
LONGMAID, HE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1213-1219
[10]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397