Polymers for bioimaging

被引:158
作者
Kim, Jong-Ho [1 ]
Park, Kyeongsoon [1 ]
Nam, Hae Yun [1 ]
Lee, Seulki [1 ]
Kim, Kwangmeyung [1 ]
Kwon, Ick Chan [1 ]
机构
[1] Korea Inst Sci & Technol, Biomed Res Ctr, Seoul 136791, South Korea
关键词
bioimaging; conjugation; imaging probes; polymer; targeting;
D O I
10.1016/j.progpolymsci.2007.05.016
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Many imaging techniques, such as optical imaging, magnetic resonance imaging, nuclear imaging, and ultrasound have been successfully utilized in clinical applications for the past decades. However, there is an urgent need to design new bioimaging probes because imaging of specific molecular pathways in vivo, particularly those that play key roles in disease processes, is hampered by the poor sensitivity and specificity with current low molecular weight imaging compounds. Recently, interdisciplinary research at the interface of polymer chemistry and the bioimaging sciences has led to the generation of polymer-based bioimaging probes for the diagnosis and treatment of disease. A combination of imaging modality and several biocompatible and/or biodegradable synthetic and natural polymers such as multivalent, branched, graft, and block copolymers, polysaccharides and dendrimers, has produced bioimaging probes which have prolonged plasma half-lives, enhanced stability, reduced toxicity, and improved target specificity. Bioimaging facilitates the integration of complex biological phenomena into the rapid visualization process in molecular levels, and are extending the applications into therapy and high throughput drug screening. This review describes the current advances in polymers for bioimaging and highlights their potentials in clinical applications. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1031 / 1053
页数:23
相关论文
共 130 条
[1]   Comparison of gadolinium-DTPA and macromolecular gadolinium-DTPA-polylysine for contrast-enhanced pulmonary time-of-flight magnetic resonance angiography [J].
Bock, JC ;
Kaufmann, F ;
Felix, R .
INVESTIGATIVE RADIOLOGY, 1996, 31 (10) :652-657
[2]  
BOGDANOV AA, 1994, J NUCL MED, V35, P1880
[3]  
Bokor D, 2000, AM J CARDIOL, V86, p19G
[4]   Optical probes and techniques for molecular contrast enhancement in coherence imaging [J].
Boppart, SA ;
Oldenburg, AL ;
Xu, CY ;
Marks, DL .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[5]   In vivo molecular target assessment of matrix metalloproteinase inhibition [J].
Bremer, C ;
Tung, CH ;
Weissleder, R .
NATURE MEDICINE, 2001, 7 (06) :743-748
[6]   Imaging of differential protease expression in breast cancers for detection of aggressive tumor phenotypes [J].
Bremer, C ;
Tung, CH ;
Bogdanov, A ;
Weissleder, R .
RADIOLOGY, 2002, 222 (03) :814-818
[7]   Optical imaging of matrix metalloproteinase-2 activity in tumors: Feasibility study in a mouse model [J].
Bremer, C ;
Bredow, S ;
Mahmood, U ;
Weissleder, R ;
Tung, CH .
RADIOLOGY, 2001, 221 (02) :523-529
[8]   Slow clearance gadolinium-based extracellular and intravascular contrast media for three-dimensional MR angiography [J].
Bremerich, J ;
Colet, JM ;
Giovenzana, GB ;
Aime, S ;
Scheffler, K ;
Laurent, S ;
Bongartz, G ;
Muller, RN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :588-593
[9]   Iron oxide MR contrast agents for molecular and cellular imaging [J].
Bulte, JWM ;
Kraitchman, DL .
NMR IN BIOMEDICINE, 2004, 17 (07) :484-499
[10]   Peptide-labeled near-infrared quantum dots for imaging tumor vasculature in living subjects [J].
Cai, WB ;
Shin, DW ;
Chen, K ;
Gheysens, O ;
Cao, QZ ;
Wang, SX ;
Gambhir, SS ;
Chen, XY .
NANO LETTERS, 2006, 6 (04) :669-676