Tethered protein/peptide-surface-modified hydrogels

被引:14
作者
Bi, JJ [1 ]
Downs, JC [1 ]
Jacob, JT [1 ]
机构
[1] Louisiana State Univ, Ctr Eye, Hlth Sci Ctr, New Orleans, LA 70112 USA
关键词
PEGylation; extracellular matrix proteins; PHEMA/MAA hydrogel; surface modification; mechanical properties; XPS;
D O I
10.1163/1568562041271084
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated a wet chemistry method to covalently bond polyethylene glycol (PEG)tethered extracellular matrix (ECM) proteins (laminin and fibronectin) or peptide (fibronectin-adhesion-peptide sequence) onto the surface of a poly(2-hydroxylethyl methacrylate-co-methylacrylic acid) (PHEMA/MAA) hydrogel that could potentially be used as a replacement for corneal tissue in the eye. An essential requirement for the success of such a surface in the biological environment is its ability to support the growth and attachment of corneal epithelial cells; ECM proteins are known to promote cellular attachment and growth. We hypothesized that the use of tethers or long hydrophilic chains would allow the attached ECM protein/peptide molecules to move two-dimensionally in space, thereby increasing their ability to bind with epithelial cell membranes. Additionally, the tethers would prevent the specifically added growth-enhancing factors from being obscured by any non-specific protein binding occurring on the hydrogel surface. In this surface-modification study, carbodiimidazole (CDI) was used to activate the carboxylic groups (-COOH) on the hydrogel surface in anhydrous dimethylsulfoxide (DMSO) before addition of the PEGylated proteins/peptide. The resulting tethered protein/peptide surface-modified hydrogels were analyzed in terms of percent grafting efficiency, biological activity and mechanical properties. X-ray photoelectron spectroscopy (XPS) and I-125 radioactive labeling demonstrated the successful covalent bonding between the moieties and the hydrogel surface. Radiolabeling and enzyme-linked immunosorbent assay (ELISA) studies indicated that the tethered proteins attached to the hydrogel surface at a concentration of approx. 0.1 mug/cm(2). ELISA testing further showed that tethered proteins remained biologically active. However, mechanical tensile testing indicated that the mechanical properties of these chemically modified hydrogels were somewhat altered in comparison with the unmodified hydrogel. Future studies will evaluate the cellular response to these surface-modified materials in vitro and in vivo.
引用
收藏
页码:905 / 916
页数:12
相关论文
共 31 条
[1]  
Agresti A., 1990, Analysis of categorical data
[2]   STUDIES OF THE ESTERIFICATION OF DEXTRAN - ROUTES TO BIOACTIVE POLYMERS AND GRAFT-COPOLYMERS [J].
BAMFORD, CH ;
MIDDLETON, IP ;
ALLAMEE, KG .
POLYMER, 1986, 27 (12) :1981-1985
[3]   An overview of the development of artificial corneas with porous skirts and the use of PHEMA for such an application [J].
Chirila, TV .
BIOMATERIALS, 2001, 22 (24) :3311-3317
[4]  
Franco M, 2000, J BIOMED MATER RES, V52, P261, DOI 10.1002/1097-4636(200011)52:2<261::AID-JBM4>3.0.CO
[5]  
2-2
[6]  
Goodman M, 1998, BIOPOLYMERS, V47, P127, DOI 10.1002/(SICI)1097-0282(1998)47:2<127::AID-BIP2>3.0.CO
[7]  
2-W
[8]   Cryogenic ultrahigh vacuum manipulator for angle dependent x-ray photoelectron spectroscopy studies [J].
Hawkridge, AM ;
Gardella, JA ;
Sagerman, GR .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2000, 18 (02) :567-569
[9]  
HSIUE GH, 1994, BIOMATERIALS, V15, P163
[10]  
HSIUE GH, 1993, BIOMATERIALS, V14, P591