Application of rhodamine B hydrazide as a new fluorogenic indicator in the highly sensitive determination of hydrogen peroxide and glucose based on the catalytic effect of iron(III)-tetrasulfonato-phthalocyanine

被引:16
作者
Chen, Xiaolan [1 ]
Zou, Jianli [1 ]
机构
[1] Xiamen Univ, Dept Chem, Coll Chem & Chem Engn, Xiamen 361005, Peoples R China
关键词
fluorimetric method; hydrogen peroxide; rhodamine B hydrazide;
D O I
10.1007/s00604-006-0685-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, selective and rapid spectrofluorimetric method is proposed for the determination of hydrogen peroxide using rhodamine B hydrazide as a fluorogenic substrate catalyzed by iron(III)-tetrasulfonatophthalocyanine. It is based on the oxidation of rhodamine B hydrazide, a colorless, non-fluorescent spirolactam hydrazide, by hydrogen peroxide which generates the highly fluorescent product rhodamine B. Under optimum conditions, the responses for hydrogen peroxide were linear from 2.0 x 10(-8) to 2.0 x 10(-6) mol L-1, with a detection limit of 3.7 x 10(-9) mol L-1 in a 3.5 min reaction period. It can easily be incorporated into the determination of biochemical substances that produce hydrogen peroxide under catalytic oxidation in the presence of their oxidase. The possibility has been tested for the determination of glucose in human sera as an example.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 21 条
[1]   FLOW SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF HYDROGEN-PEROXIDE USING A CATION-EXCHANGER FOR PRECONCENTRATION [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :159-163
[2]   Application of iron-tetrasulfonatophthalocyanine as a new mimetic peroxidase in the determination of hydrogen peroxide with p-hydroxyphenylpropionic acid as a substrate [J].
Chen, QY ;
Li, DH ;
Zhu, QZ ;
Zheng, H ;
Xu, JG .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :175-182
[3]   Study of tetra-substituted amino aluminum phthalocyanine as a new red-region substrate for the fluorometric determination of peroxidase and hydrogen peroxide [J].
Chen, XL ;
Li, DH ;
Yang, HH ;
Zhu, QZ ;
Zheng, H ;
Xu, JG .
ANALYTICA CHIMICA ACTA, 2001, 434 (01) :51-58
[4]   A long-wavelength fluorescent chemodosimeter selective for Cu(II) ion in water [J].
Dujols, V ;
Ford, F ;
Czarnik, AW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (31) :7386-7387
[5]  
Gündogan-Paul M, 2002, ELECTROANAL, V14, P505, DOI 10.1002/1521-4109(200204)14:7/8<505::AID-ELAN505>3.0.CO
[6]  
2-#
[7]   FLUOROMETRIC FLOW-INJECTION DETERMINATION OF AQUEOUS PEROXIDES AT NANOMOLAR LEVEL USING MEMBRANE REACTORS [J].
HWANG, H ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1521-1524
[8]   DEVELOPMENT OF A NOVEL LUMINOL-RELATED COMPOUND, 3-PROPYL-7,8-DIHYDROPYRIDAZINO[4,5-G]QUINOXALINE-2,6,9(1H)-TRIONE, AND ITS APPLICATION TO HYDROGEN-PEROXIDE AND SERUM GLUCOSE ASSAYS [J].
ISHIDA, J ;
ARAKAWA, H ;
TAKADA, M ;
YAMAGUCHI, M .
ANALYST, 1995, 120 (04) :1083-1086
[9]   REAGENT-INJECTION FLOW-ANALYSIS - APPLICATION TO THE DETERMINATION OF NANOMOLAR LEVELS OF HYDROGEN-PEROXIDE IN SEAWATER [J].
JOHNSON, KS ;
SAKAMOTOARNOLD, CM ;
WILLASON, SW ;
BEEHLER, CL .
ANALYTICA CHIMICA ACTA, 1987, 201 :83-94
[10]   Fluorescent indicators for nitric oxide based on rhodamine chromophore [J].
Kojima, H ;
Hirotani, M ;
Urano, Y ;
Kikuchi, K ;
Higuchi, T ;
Nagano, T .
TETRAHEDRON LETTERS, 2000, 41 (01) :69-72