Non-Aqueous Spray Solvents and Solubility Effects in Desorption Electrospray Ionization

被引:66
作者
Badu-Tawiah, Abraham [1 ]
Bland, Celine [1 ]
Campbell, Dahlia I. [1 ]
Cooks, R. Graham [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
INTERNAL ENERGY-DISTRIBUTION; AMBIENT MASS-SPECTROMETRY; ATMOSPHERIC-PRESSURE; DESI; COMPLEX; DISTRIBUTIONS; MECHANISMS; GENERATION; SOLIDS; URINE;
D O I
10.1016/j.jasms.2009.12.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of non-aqueous solvents in desorption electrospray ionization mass spectrometry (DESI-MS) is explored by analyzing a set of 43 compounds using binary mixtures of chloroform, tetrahydrofuran, and acetonitrile as the spray solvent. Comparisons of data obtained from chloroform/tetrahydrofuran (1:1) and chloroform/acetonitrile (1:1) spray solvents with the standard aqueous-based spray solvent (methanol/water, 1:1) shows that the non-aqueous systems have practical value for DESI, especially in the analysis of hydrophobic compounds. Non-aqueous spray solvents were used to ionize thermometer molecules (benzyl pyridinium salts) and showed lower internal energies (softer DESI ionization compared with methanol/water, 1:1), a result that has parallels in known solvent effects in electrospray ionization and is explained by solvent effects on surface tension. Consideration of octanol/water partition coefficients (K-ow) of the 43 analytes in the light of their DESI results reveals the importance of the solubility of analyte in the spray solvent in producing high quality mass spectra. This finding provides additional support for the droplet pick-up description of the DESI mechanism, which is based on analyte dissolution in the spray solvent, followed by splashing of subsequently arriving droplets in the liquid film to form microdroplets of dissolved analyte. DESI solvent optimization can be improved by the use of K-ow of the analyte as an indication of the polarity of the most appropriate solvent system. (J Am Soc Mass Spectrom 2010, 21, 572-579) (C) 2010 American Society for Mass Spectrometry
引用
收藏
页码:572 / 579
页数:8
相关论文
共 48 条
[1]   Determination of fungicide residues in fruits and vegetables by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [J].
Blasco, C ;
Picó, Y ;
Mañes, J ;
Font, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (02) :227-235
[2]   Direct measurement of octanol-water partition coefficients of some environmentally relevant brominated diphenyl ether congeners [J].
Braekevelt, E ;
Tittlemier, SA ;
Tomy, GT .
CHEMOSPHERE, 2003, 51 (07) :563-567
[3]   THE COMPARATIVE PHARMACOKINETICS AND TISSUE PENETRATION OF SINGLE-DOSE CIPROFLOXACIN 400 MG IV AND 750 MG PO [J].
CATCHPOLE, C ;
ANDREWS, JM ;
WOODCOCK, J ;
WISE, R .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1994, 33 (01) :103-110
[4]  
Chen H, 2006, CHEM COMMUN, P597, DOI 10.1039/b516448f
[5]   Neutral desorption sampling of living objects for rapid analysis by extractive electrospray ionization mass spectrometry [J].
Chen, Huanwen ;
Yang, Shuiping ;
Wortmann, Arno ;
Zenobi, Renato .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (40) :7591-7594
[6]   Extractive electrospray ionization for direct analysis of undiluted urine, milk and other complex mixtures without sample preparation [J].
Chen, HW ;
Venter, A ;
Cooks, RG .
CHEMICAL COMMUNICATIONS, 2006, (19) :2042-2044
[7]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[8]  
Collette C, 1998, RAPID COMMUN MASS SP, V12, P1673, DOI 10.1002/(SICI)1097-0231(19981130)12:22<1673::AID-RCM385>3.0.CO
[9]  
2-A
[10]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570