Influence of the quality of tibial plateau alignment on the reproducibility of computer joint space measurement from Lyon schuss radiographic views of the knee in patients with knee osteoarthritis

被引:42
作者
Conrozier, T
Favret, H
Mathieu, P
Piperno, M
Provvedini, D
Taccoen, A
Colson, F
Conrozier, S
Vignon, E
机构
[1] Ctr Hosp Lyon Sud, Serv Rhumatol, Pierre Benite, France
[2] LEMA, Lyon, France
[3] NEGMA, LERADS, Toussus Le Noble, France
[4] Ctr Rhumatol Lyon Presquile, Lyon, France
关键词
osteoarthritis; knee; radiograph; joint space; schuss; computer measurement;
D O I
10.1016/j.joca.2004.06.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rationale: The quality of medial tibial plateau (MT-Plateau) alignment is one of the key elements for accuracy and sensitivity to change of knee radiography in knee osteoarthritis (OA). Aim: To evaluate the influence of the quality of the MT-Plateau alignment on the reproducibility of joint space width (JSW) measurement in knee radiographs. Methods: One hundred and twenty-seven knee radiographs (99 OA), performed using a standardized radiographic procedure (Lyon schuss (LS) view). .Evaluation of the quality of MT-Plateau alignment. .Computerized measurement of the JSW, twice, 1-month apart, using a semi-automated and an automated method of measurement. .Assessment of the reproducibility of repeated measurements: calculation of intra-observer coefficient of correlation, smallest detectable difference (SDD) and coefficient of variation (CV). Results: MT-Plateau alignment was satisfactory in 99 radiographs (77.9%). Reproducibility was excellent in both satisfactory and non-satisfactory radiographs, irrespective of the method of measurement used. The automated measurement was more reproducible than the semi-automated one (CV 1.15% and 3.23%). SDD and CV were better in satisfactory than in non-satisfactory MT-Plateau aligned radiographs. Conclusion: These results confirm that computer measurement of the medial tibio-femoral JSW, from LS digitized radiographs, is highly reproducible, irrespective of the quality of the radiograph. However, the quality of the MT-Plateau alignment influences the reproducibility of JSW measurement. The automated measurement was more reproducible than the semi-automated one. (C) 2004 OsteoArthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:765 / 770
页数:6
相关论文
共 27 条
[11]   Trainable rule-based algorithm for the measurement of joint space width in digital radiographic images of the knee [J].
Duryea, J ;
Li, J ;
Peterfy, CG ;
Gordon, C ;
Genant, HK .
MEDICAL PHYSICS, 2000, 27 (03) :580-591
[12]   New radiographic-based surrogate outcome measures for osteoarthritis of the knee [J].
Duryea, J ;
Zaim, S ;
Genant, HK .
OSTEOARTHRITIS AND CARTILAGE, 2003, 11 (02) :102-110
[13]   RADIOLOGICAL ASSESSMENT OF OSTEO-ARTHROSIS [J].
KELLGREN, JH ;
LAWRENCE, JS .
ANNALS OF THE RHEUMATIC DISEASES, 1957, 16 (04) :494-502
[14]  
LEQUESNE M, 1994, J RHEUMATOL, V21, P2395
[15]  
LEQUESNE M, 1995, OSTEOARTHRITIS DISOR, V30, P427
[16]  
Lynch J A, 1993, Osteoarthritis Cartilage, V1, P209, DOI 10.1016/S1063-4584(05)80327-9
[17]  
Mazzuca SA, 2002, ARTHRITIS RHEUM-US, V46, P109, DOI 10.1002/1529-0131(200201)46:1<109::AID-ART10040>3.0.CO
[18]  
2-O
[19]  
Mazzuca SA, 2001, ARTHRITIS RHEUM, V44, P1786, DOI 10.1002/1529-0131(200108)44:8<1786::AID-ART315>3.0.CO
[20]  
2-L