Characterization of HPLC packings

被引:128
作者
Neue, UD [1 ]
VanTran, K [1 ]
Iraneta, PC [1 ]
Alden, BA [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
来源
JOURNAL OF SEPARATION SCIENCE | 2003年 / 26卷 / 3-4期
关键词
reversed-phase columns; characterization of packings;
D O I
10.1002/jssc.200390025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several chromatographic test procedures are in use for the characterization of commercially available packings. The results of the test procedure used in our laboratory are updated and further refined. Two well-defined physico-chemical properties of packings can be derived from this test procedure, the hydrophobicity of a packing and the silanophilic activity at pH 7. In addition, our method is unique in its ability to differentiate between classical packings and packings with incorporated polar groups. We can also distinguish CN packings or fluorinated packings. Our database now includes over 100 commercially available packings. The ability of the test to cleanly discriminate between different classes of packings has been strengthened. Limited comparisons with other published tests are now possible as well, and the results of these comparisons are discussed.
引用
收藏
页码:174 / 186
页数:13
相关论文
共 35 条
[1]   GEOMETRICAL MODEL FOR CHEMICALLY BONDED TMS AND PDS PHASES [J].
BERENDSEN, GE ;
GALAN, LD .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1978, 1 (04) :403-426
[2]   Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography [J].
Claessens, HA ;
van Straten, MA ;
Cramers, CA ;
Jezierska, M ;
Buszewski, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :135-156
[3]   CHROMATOGRAPHIC CHARACTERIZATION OF SILICA-BASED REVERSED PHASES [J].
ENGELHARDT, H ;
LOW, H ;
GOTZINGER, W .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :371-379
[4]   COMPARISON AND CHARACTERIZATION OF REVERSED PHASES [J].
ENGELHARDT, H ;
JUNGHEIM, M .
CHROMATOGRAPHIA, 1990, 29 (1-2) :59-68
[5]   POLYMER ENCAPSULATED STATIONARY PHASES - ADVANTAGES, PROPERTIES AND SELECTIVITIES [J].
ENGELHARDT, H ;
LOW, H ;
EBERHARDT, W ;
MAUSS, M .
CHROMATOGRAPHIA, 1989, 27 (11-12) :535-543
[6]  
ENGELHARDT H, 1977, HOCHDRUCKFLUSSIGKEIT
[7]  
Euerby MR, 2000, LC GC EUR, V13, P665
[8]   Minimal number of chromatographic test parameters for the characterisation of reversed-phase liquid chromatographic stationary phases [J].
Iványi, T ;
Heyden, YV ;
Visky, D ;
Baten, P ;
De Beer, J ;
Lázár, I ;
Massart, DL ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 954 (1-2) :99-114
[9]  
Kaliszan R., 1997, STRUCTURE RETENTION
[10]   Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatographic columns II.: Results obtained with Symmetry C18 columns [J].
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :55-79