Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization

被引:86
作者
Quick, HH
Zenge, MO
Kuehl, H
Kaiser, G
Aker, S
Massing, S
Bosk, S
Ladd, ME
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Transplantat Surg, D-45122 Essen, Germany
[3] Univ Hosp Essen, Dept Pathophysiol, D-45122 Essen, Germany
[4] Siemens Med Solut, Erlangen, Germany
关键词
interventional MRA; wireless active instrument visualization; inductive coupling; interventional device tracking; catheter RF coils; projection reconstruction (PR); selective MRA;
D O I
10.1002/mrm.20347
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument to background contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B-0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention. (C) 2005 WileyLiss, Inc.
引用
收藏
页码:446 / 455
页数:10
相关论文
共 45 条
[1]   Signal-to-noise ratio comparison between surface coils and implanted coils [J].
Arnder, LL ;
Shattuck, MD ;
Black, RD .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :727-733
[2]   High resolution intravascular MRI and MRS by using a catheter receiver coil [J].
Atalar, E ;
Bottomley, PA ;
Ocali, O ;
Correia, LCL ;
Kelemen, MD ;
Lima, JAC ;
Zerhouni, EA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :596-605
[3]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[4]   MR-Guided intravascular procedures:: Real-time parameter control and automated slice positioning with active tracking coils [J].
Bock, M ;
Volz, S ;
Zühlsdorff, S ;
Umathum, R ;
Fink, C ;
Hallscheidt, P ;
Semmler, W .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) :580-589
[5]  
Bos C, 2000, MAGN RESON MED, V44, P575, DOI 10.1002/1522-2594(200010)44:4<575::AID-MRM11>3.0.CO
[6]  
2-S
[7]  
Burl M, 1999, MAGNET RESON MED, V41, P636, DOI 10.1002/(SICI)1522-2594(199903)41:3<636::AID-MRM30>3.0.CO
[8]  
2-A
[9]  
Burl M, 1996, MAGNET RESON MED, V36, P491, DOI 10.1002/mrm.1910360326
[10]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415