The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) study: Rationale and design

被引:20
作者
Burri, Haran [1 ]
Quesada, Aurelio [2 ]
Ricci, Renato Pietro [3 ]
Boriani, Giuseppe [4 ]
Davinelli, Mario [5 ]
Favale, Stefano [6 ]
Da Costa, Antoine [7 ]
Kautzner, Josef [8 ]
Moser, Raymond [9 ]
Navarro, Xavier [10 ]
Santini, Massimo [3 ]
机构
[1] Univ Hosp Geneva, CH-1211 Geneva 14, Switzerland
[2] Univ Gen Hosp, Valencia, Spain
[3] San Filippo Neri Hosp, Rome, Italy
[4] Univ Bologna, Inst Cardiol, Bologna, Italy
[5] Medtronic, Milan, Italy
[6] Univ Hosp, Bari, Italy
[7] Univ Hosp, St Etienne, France
[8] IKEM, Prague, Czech Republic
[9] Medtron Schweiz, Bern, Switzerland
[10] Medtron Iberica, Madrid, Spain
关键词
CHRONIC HEART-FAILURE; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; ATRIAL-FIBRILLATION; FOLLOW-UP; TRIAL; GUIDELINES; MANAGEMENT; PACEMAKERS; THERAPY; TIME;
D O I
10.1016/j.ahj.2010.04.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background With the advent of remote monitoring, current models of implantable cardioverter defibrillators (ICDs) have the possibility of sending automatic alert messages that allow early diagnosis of events such as lung fluid overload, atrial fibrillation and device integrity issues. Timely treatment of these events has the potential to improve patient outcome, but this has not as yet been proven. Methods The MORE-CARE study is a multicenter randomized controlled trial evaluating the efficacy of advanced device diagnostics and remote monitoring in improving the outcome of patients with biventricular ICDs. Up to 1720 patients with a standard indication for a biventricular ICD will be randomized to standard in-office follow-up, or to a remote monitoring strategy using the CareLink network and involving automatic alerts for lung fluid overload, atrial fibrillation, and device integrity issues. The first phase aims at evaluating the delay between an alert event, and clinical action to the event. The second phase of the study will evaluate whether the remote monitoring strategy results in a significant reduction of a combined end point of total mortality or cardiovascular and device-related hospitalization. The duration of the study will be event-driven due to its sequential design. Conclusion MORE-CARE will evaluate the efficacy of remote monitoring for improving patient outcome in patients implanted with a biventricular ICD. (Am Heart J 2010; 160: 42-8.)
引用
收藏
页码:42 / 48
页数:7
相关论文
共 21 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]  
ABRAHAM WT, 2009, HEART FAIL SOC AM SC
[3]  
ALKHATIB SM, 2009, J CARDIOVASC ELECTRO
[4]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[5]   Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators [J].
Burri, Haran ;
Senouf, David .
EUROPACE, 2009, 11 (06) :701-709
[6]   Monitored atrial fibrillation duration predicts arterial embolic events in patients suffering from bradycardia and atrial fibrillation implanted with antitachycardia pacemakers [J].
Capucci, A ;
Santini, M ;
Padeletti, L ;
Gulizia, M ;
Botto, G ;
Boriani, G ;
Ricci, R ;
Favale, S ;
Zolezzi, F ;
Di Belardino, N ;
Molon, G ;
Drago, F ;
Villani, GQ ;
Mazzini, E ;
Vimercati, M ;
Grammatico, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (10) :1913-1920
[7]   Longer-term effects of cardiac resynchronization therapy on mortality in heart failure [the CArdiac REsynchronization-Heart Failure (CARE-HF) trial extension phase] [J].
Cleland, John G. F. ;
Daubert, Jean-Claude ;
Erdmann, Erland ;
Freemantle, Nick ;
Gras, Daniel ;
Kappenberger, Lukas ;
Tavazzi, Luigi .
EUROPEAN HEART JOURNAL, 2006, 27 (16) :1928-1932
[8]   Trial design of the clinical evaluation of remote notification to reduce time to clinical decision: The Clinical evaluation Of remote NotificatioN to rEduCe Time to clinical decision (CONNECT) study [J].
Crossley, George ;
Boyle, Andrew ;
Vitense, Holly ;
Sherfesee, Lou ;
Mead, R. Hardwin .
AMERICAN HEART JOURNAL, 2008, 156 (05) :840-846
[9]  
CROSSLEY GH, 2010, AM COLL CARD ANN SCI
[10]   ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008 [J].
Dickstein, Kenneth ;
Cohen-Solal, Alain ;
Filippatos, Gerasimos ;
McMurray, John J. V. ;
Ponikowski, Piotr ;
Poole-Wilson, Philip Alexander ;
Stromberg, Anna ;
van Veldhuisen, Dirk J. ;
Atar, Dan ;
Hoes, Arno W. ;
Keren, Andre ;
Mebazaa, Alexandre ;
Nieminen, Markku ;
Priori, Silvia Giuliana ;
Swedberg, Karl .
EUROPEAN HEART JOURNAL, 2008, 29 (19) :2388-2442