Bioanalytical applications of accelerator mass spectrometry for pharmaceutical research

被引:66
作者
Turteltaub, KW
Vogel, JS
机构
[1] Lawrence Livermore Natl Lab, Ctr Accelerator Mass Spectrometry & Biol, Livermore, CA 94551 USA
[2] Lawrence Livermore Natl Lab, Biol Res Program, Livermore, CA 94551 USA
关键词
D O I
10.2174/1381612003400047
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Accelerator mass spectrometry (AMS) is a mass spectrometric method for quantifying isotopes. It has had great impact in the geosciences and is now being applied in the biomedical fields. AMS measures radioisotopes such as C-14, H-3, C-41, and Cl-36, and others, with attomole sensitivity and high precision. Its use is allowing absorption, distribution, metabolism and elimination studies, as well as detailed pharmacokinetics, to be carried out directly in humans with very low chemical or radiological hazard. It is used in combination with standard separation methodologies, such as chromatography, in identification of metabolites and molecular targets for both toxicants and pharmacologic agents. AMS allows the use of very low specific activity chemicals (less than or equal to 1 mCi/mmol), creating opportunities to use compounds not available in a high specific activity form, such as those that must be biosynthesized, produced in combinatorial libraries, or made through inefficient synthesis. AMS is allowing studies to be carried out with agents having low bioavailability, low systemic distributions, or high toxicity where administered doses must be kept low (less than or equal to 1 mu g/kg). It may have uses in tests for idiosyncratic metabolism, drug interaction, or individual susceptibility, among others. The ability to use very low chemical doses, low radiological doses, small samples and conduct multiple dose studies may help move drug candidates into humans faster and safer than before. The uses of AMS are growing and its potential for drug development is only now beginning to be realized.
引用
收藏
页码:991 / 1007
页数:17
相关论文
共 79 条
[1]   CRIMS - CHEMICAL-REACTION INTERFACE MASS-SPECTROMETRY [J].
ABRAMSON, FP .
MASS SPECTROMETRY REVIEWS, 1994, 13 (04) :341-356
[2]   ION SOURCES FOR ACCELERATORS IN MATERIALS RESEARCH [J].
ALTON, GD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 73 (02) :221-288
[3]  
Barker J, 1999, RAPID COMMUN MASS SP, V13, P285, DOI 10.1002/(SICI)1097-0231(19990228)13:4<285::AID-RCM469>3.3.CO
[4]  
2-I
[5]   RADIOCARBON DATING USING ELECTROSTATIC ACCELERATORS - NEGATIVE-IONS PROVIDE KEY [J].
BENNETT, CL ;
BEUKENS, RP ;
CLOVER, MR ;
GOVE, HE ;
LIEBERT, RB ;
LITHERLAND, AE ;
PURSER, KH ;
SONDHEIM, WE .
SCIENCE, 1977, 198 (4316) :508-510
[6]   Synthesis and evaluation of potential N-pi and N-sigma metal chelation sites within the beta-hydroxy-L-histidine subunit of bleomycin A(2): Functional characterization of imidazole N-pi metal complexation [J].
Boger, DL ;
Ramsey, TM ;
Cai, H .
BIOORGANIC & MEDICINAL CHEMISTRY, 1996, 4 (02) :195-207
[7]   A GASEOUS ION-SOURCE FOR ROUTINE AMS RADIOCARBON DATING [J].
BRONK, CR ;
HEDGES, REM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 52 (3-4) :322-326
[8]   IMPROVED COLLAGEN EXTRACTION BY MODIFIED LONGIN METHOD [J].
BROWN, TA ;
NELSON, DE ;
VOGEL, JS ;
SOUTHON, JR .
RADIOCARBON, 1988, 30 (02) :171-177
[9]   Intrinsic erythrocyte labeling and attomole pharmacokinetic tracing of 14C-labeled folic acid with accelerator mass spectrometry [J].
Buchholz, BA ;
Arjomand, A ;
Dueker, SR ;
Schneider, PD ;
Clifford, AJ ;
Vogel, JS .
ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) :348-352
[10]  
BUCHHOLZ BA, 1999, IN PRESS ANAL CHEM