Detection of two distinct substrate-dependent catabolic responses in yeast cells using a mediated electrochemical method

被引:74
作者
Baronian, KHR
Downard, AJ
Lowen, RK
Pasco, N
机构
[1] Christchurch Polytech Inst Technol, Sch Appl Sci, Christchurch, New Zealand
[2] Univ Canterbury, Dept Chem, Christchurch 1, New Zealand
[3] Lincoln Univ, Lincoln Ventures Ltd, Canterbury, New Zealand
关键词
D O I
10.1007/s00253-002-1108-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Mediated electrochemical detection of catabolism in prokaryotic cells is well documented; however, the application of this technique to eukaryotic cells has received less attention. Two catabolic substrate-dependent mediated electrochemical signals were detected in the yeast Saccharomyces cerevisiae. The signal using a single hydrophilic mediator (ferricyanide) is small whereas the response using a double mediator system comprising a hydrophilic and a lipophilic mediator (ferricyanide and menadione) is up to three orders of magnitude larger. The behaviour of each response during cell ageing is different: the single mediator response increases whereas the double mediator response decreases. This difference indicates that the two signals originate at different points in the catabolic pathways. In S. cerevisiae the double mediator response is proposed to originate from the reduction of the lipophilic mediator by NADPH produced in the pentose phosphate pathway. The single mediator signal arises from reduction of the hydrophilic mediator by an extracellular redox species produced in response to the presence of glucose.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 19 条
[11]   Potentiometric measurement of intracellular redox activity [J].
Rabinowitz, JD ;
Vacchino, JF ;
Beeson, C ;
McConnell, HM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (10) :2464-2473
[12]   DEVELOPMENT OF AN ELECTROCHEMICAL METHOD FOR THE RAPID-DETERMINATION OF MICROBIAL CONCENTRATION AND EVIDENCE FOR THE REACTION-MECHANISM [J].
RAMSAY, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) :61-69
[13]  
RAWSON DM, 1987, TOXIC ASSESS, V2, P325
[14]   A CHEMICALLY MEDIATED AMPEROMETRIC BIOSENSOR FOR MONITORING EUBACTERIAL RESPIRATION [J].
RICHARDSON, NJ ;
GARDNER, S ;
RAWSON, DM .
JOURNAL OF APPLIED BACTERIOLOGY, 1991, 70 (05) :422-426
[15]  
Subrahmanyam S, 2001, ELECTROANAL, V13, P1454
[16]   MICROBIAL MEMBRANE-MODIFIED DISSOLVED-OXYGEN PROBE FOR RAPID BIOCHEMICAL OXYGEN-DEMAND MEASUREMENT [J].
TAN, TC ;
LI, F ;
NEOH, KG ;
LEE, YK .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (02) :167-172
[17]   BOD BIOSENSOR FOR SECONDARY EFFLUENT FROM WASTE-WATER TREATMENT PLANTS [J].
TANAKA, H ;
NAKAMURA, E ;
MINAMIYAMA, Y ;
TOYODA, T .
WATER SCIENCE AND TECHNOLOGY, 1994, 30 (04) :215-227
[18]   Mediated microbial biosensor using a novel yeast strain for wastewater BOD measurement [J].
Trosok, SP ;
Driscoll, BT ;
Luong, JHT .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2001, 56 (3-4) :550-554
[19]  
Walker G.M., 1998, Yeast physiology and biotechnology