Simultaneous detection of purine and pyrimidine at highly boron-doped diamond electrodes by using liquid chromatography

被引:111
作者
Ivandini, Tribidasari A. [1 ,2 ]
Honda, Kensuke [3 ]
Rao, Tata. N. [4 ]
Fujishima, Akira [5 ]
Einaga, Yasuaki [1 ]
机构
[1] Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
[2] Univ Indonesia, Fac Math & Sci, Dept Chem, Jakarta 4240041, Indonesia
[3] Yamaguchi Univ, Fac Sci, Dept Chem & Earth Sci, Yamaguchi 7538512, Japan
[4] Int Adv Res Ctr Powder Metallurgy & New Mat ARCI, Hyderabad 500005, Andhra Pradesh, India
[5] Kanagawa Acad Sci & Technol, Kawasaki, Kanagawa 2130012, Japan
关键词
purine; pyrimidine; DNA damage; anodically oxidized diamond; liquid chromatography;
D O I
10.1016/j.talanta.2006.05.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly boron-doped diamond (BDD) electrode, have been examined for simultaneous detection of purine and pyrimidine bases in mild acidic media by using HPLC with amperometric detection. Cyclic voltammetry at as-deposited (AD) and anodically oxidized (AO) BDD were used to study the electrochemistry and to optimize the condition for HPLC applications. At AO BDD electrode, due to its higher overpotential of oxygen evolution reaction, well-defined anodic peaks were observed for the oxidation of purine and pyrimidine bases in acid medium, whereas at AD BDD the oxidation peak of thymine was overlapped with the anodic cur-rent of oxygen evolution. The chromatograms of adenine, guanine, cytosine, thymine and 5-methylcytosine mixture were well resolved by using a silica-based column and a solution of 5% acetonitrile in 100 mM ammonium acetate buffer (pH 4.25) as the mobile phase. The detection was carried out at AO BDD electrode at an applied potential of 1.6 V versus Ag/AgCl. Linear calibration curves were obtained within the concentration range from 0.1 to 10 mu M with the limits of detection (S/N = 3) ranging from 26.3 to 162.1 nM, resulting in an order of magnitude higher sensitivities than those at conventional electrodes. HPLC analysis with diamond amperometric detector was successfully applied for determination of 5-methylcytosine in real DNA samples with high reproducibility. No deactivation of the electrode was found during cyclic voltammetric and HPLC measurements, indicating the high stability for analysis of biological samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:648 / 655
页数:8
相关论文
共 39 条
[1]  
Brown W. H., 1987, Introduction to Organic and Biochemistry, V4th, P418
[2]   NUCLEAR MATRIX-ASSOCIATED DNA METHYLASE [J].
BURDON, RH ;
QURESHI, M ;
ADAMS, RLP .
BIOCHIMICA ET BIOPHYSICA ACTA, 1985, 825 (01) :70-79
[3]   Determination of purine and pyrimidine bases in DNA by micellar electrokinetic capillary chromatography with electrochemical detection [J].
Chen, G ;
Han, XH ;
Zhang, LY ;
Ye, JN .
JOURNAL OF CHROMATOGRAPHY A, 2002, 954 (1-2) :267-276
[4]   Separation of six purine bases by capillary electrophoresis with electrochemical detection [J].
Chen, G ;
Chu, QC ;
Zhang, LY ;
Ye, JN .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :225-233
[5]   Morphological and microstructural stability of boron-doped diamond thin film electrodes in an acidic chloride medium at high anodic current densities [J].
Chen, QY ;
Granger, MC ;
Lister, TE ;
Swain, GM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (11) :3806-3812
[6]   Simultaneous determination of multiple constituents in real beer samples of different origins by capillary zone electrophoresis [J].
Cortacero-Ramírez, S ;
Segura-Carretero, A ;
Cruces-Blanco, C ;
Romero-Romero, M ;
Fernández-Gutiérrez, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (5-6) :831-837
[7]   ANALYSIS OF 5-METHYLCYTOSINE IN DNA BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CRAIN, PF .
METHODS IN ENZYMOLOGY, 1990, 193 :857-865
[8]   Elimination of stress-induced defects in polybuffered LOCOS isolation scheme for sub-0.25 mu m designs [J].
Deleonibus, S ;
Martin, F ;
Heitzmann, M ;
Guibert, JC ;
Papon, AM .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (06) :L164-L166
[9]  
DRYHURST G, 1977, ELECTROCHEMISTRY BIO, P80
[10]   QUANTITATIVE-DETERMINATION OF 5-METHYLCYTOSINE IN DNA BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
EICK, D ;
FRITZ, HJ ;
DOERFLER, W .
ANALYTICAL BIOCHEMISTRY, 1983, 135 (01) :165-171