Left ventricular assist device performance with long-term circulatory support: Lessons from the REMATCH trial

被引:119
作者
Dembitsky, WP
Tector, AJ
Park, S
Moskowitz, AJ
Gelijns, AC
Ronan, NS
Piccione, W
Holman, WL
Furukawa, S
Frazier, OH
Weinberg, AD
Heatley, G
Poirier, VL
Damme, L
Long, JW
机构
[1] Columbia Univ, InCHOIR, New York, NY 10032 USA
[2] St Lukes Hosp, Milwaukee, WI USA
[3] Sharp Mem Hosp & Rehabil Ctr, San Diego, CA 90034 USA
[4] Calif Pacific Med Ctr, San Francisco, CA USA
[5] Rush Presbyterian St Lukes Med Ctr, Chicago, IL 60612 USA
[6] Univ Alabama Birmingham, Birmingham, AL USA
[7] Temple Univ Hosp & Med Sch, Philadelphia, PA 19140 USA
[8] Thoratec Corp, Pleasanton, CA USA
[9] Latter Day St Hosp, Salt Lake City, UT 84143 USA
关键词
D O I
10.1016/j.athoracsur.2004.02.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Left ventricular assist device (LVAD) failure and malfunction rates are critical gauges for establishing LVADs as a long-term therapy for end-stage heart failure patients. These device performance measures, however, have been inadequately characterized in the bridge-to-transplantation literature. Methods. REMATCH is a randomized trial that compares optimal medical management with LVAD implantation for patients with end-stage heart failure. An independent committee adjudicated patient outcomes. The primary endpoint-survival-was analyzed by intention to treat using the log-rank statistic. Frequency of event occurrence was analyzed by Poisson regression. The time to first event was analyzed by the product limit method. Device performance was disaggregated into confirmed malfunctions and system failures. The latter were events in which patients could not be rescued with backup circulatory support measures. Results. The 1-year survival rate was 52% (95% confidence limit [CL]; 40%-63%) for LVAD patients versus 28% (95% CL; 17%-39%) for medical patients and the 2-year survival rate was 29% (95% CL; 19%-40%) for LVAD patients versus 13% (95% CL; 5%-22%) for medical patients. System failure was 0.13 per patient per year and the confirmed LVAD malfunction rate was 0.90. Freedom from device replacement was 87% at 1 year and 37% at 2 years. Conclusions. Despite the observed rates of device malfunction and replacement, LVAD implantation confers clinically significant improvement with regard to survival as compared with medical management. Device modifications and innovations for infection management exhibit great promise of improving device performance in the near future. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:2123 / 2129
页数:7
相关论文
共 8 条
[1]  
Geert V, 2000, LINEAR MIXED MODELS
[2]  
HOLMAN WL, 2004, IN PRESS J HEART LUN
[3]   NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS [J].
KAPLAN, EL ;
MEIER, P .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) :457-481
[4]   Neurological events during long-term mechanical circulatory support for heart failure - The Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience [J].
Lazar, RM ;
Shapiro, PA ;
Jaski, BE ;
Parides, MK ;
Bourge, RC ;
Watson, JT ;
Damme, L ;
Dembitsky, W ;
Hosenpud, JD ;
Gupta, L ;
Tierney, A ;
Kraus, T ;
Naka, Y .
CIRCULATION, 2004, 109 (20) :2423-2427
[5]   Left ventricular assist devices as permanent heart failure therapy - The price of progress [J].
Oz, MC ;
Gelijns, AC ;
Miller, L ;
Wang, CL ;
Nickens, P ;
Arons, R ;
Aaronson, K ;
Richenbacher, W ;
van Meter, C ;
Nelson, K ;
Weinberg, A ;
Watson, J ;
Rose, EA ;
Moskowitz, AJ .
ANNALS OF SURGERY, 2003, 238 (04) :577-583
[6]   ASSESSMENT OF PATIENT OUTCOME WITH THE MINNESOTA LIVING WITH HEART-FAILURE QUESTIONNAIRE - RELIABILITY AND VALIDITY DURING A RANDOMIZED, DOUBLE-BLIND, PLACEBO-CONTROLLED TRIAL OF PIMOBENDAN [J].
RECTOR, TS ;
COHN, JN .
AMERICAN HEART JOURNAL, 1992, 124 (04) :1017-1025
[7]   Long-term use of a left ventricular assist device for end-stage heart failure [J].
Rose, EA ;
Gelijns, AC ;
Moskowitz, AJ ;
Heitjan, DF ;
Stevenson, LW ;
Dembitsky, W ;
Long, JW ;
Ascheim, DD ;
Tierney, AR ;
Levitan, RG ;
Watson, JT ;
Meier, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) :1435-1443
[8]   The REMATCH trial: Rationale, design, and end points [J].
Rose, EA ;
Moskowitz, AJ ;
Packer, M ;
Sollano, JA ;
Williams, DL ;
Tierney, AR ;
Heitjan, DF ;
Meier, P ;
Ascheim, DD ;
Levitan, RG ;
Weinberg, AD ;
Stevenson, LW ;
Shapiro, PA ;
Lazar, RM ;
Watson, JT ;
Goldstein, DJ ;
Gelijns, AC .
ANNALS OF THORACIC SURGERY, 1999, 67 (03) :723-730