Hemodynamic and catecholamine response to tracheal intubation: Direct laryngoscopy compared with fiberoptic intubation

被引:46
作者
Barak, M
Ziser, A
Greenberg, A
Lischinsky, S
Rosenberg, B
机构
[1] Rambam Med Ctr, Dept Anesthesiol, IL-31096 Haifa, Israel
[2] Rambam Med Ctr, Dept Clin Biochem, IL-31096 Haifa, Israel
[3] Technion Fac Med, Dept Anesthesiol, Haifa, Israel
关键词
cardiovascular response; catecholamines; fiberoptic intubation; laryngoscopy;
D O I
10.1016/S0952-8180(02)00514-7
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To compare the stress response following tracheal intubation using direct laryngoscopy to that using fiberaptic bronchoscopy technique. Design: Randomized, prospective study. Patients: 51 ASA physical status I and II patients who were scheduled for an elective surgery with general anesthesia. Interventions: Patients were randomly assigned to receive either direct laryngoscopy or fiberoptic orotracheal intubation, as part of general anesthesia. A uniform protocol of anesthetic medications was used. Measurements: Blood pressure and heart rate were measured before induction, before endotracheal intubation, and 1, 2, 3, and 5 minutes afterwards. Catecholamine (epinephrine and norepinephrine) blood samples were drawn before the induction, and I and 5 minutes after intubation. Main Results: Duration of intubation was shorter in the direct laryngoscopy group (16 9 (16.9 +/- 7.0 sec, range 8 to 40) compared with the fiberoptic intubation group (55.0 +/- 22.5 sec, range 29 to 120), p < 0.0,001. In both groups, blood pressure and heart rate were significantly increased at 1, 2, and 3 minutes after intubation, but there was no significant difference between the two study groups. Catecholamine Levels did not increase after intubation and did not correlate with the hemodynamic changes. Conclusions: The use of either direct laryngoscopy or fiberoptic bronchoscopy produces a comparable stress response to tracheal intubation. Catecholamine Levels do not correlate with the hemodynamic changes. (C) 2003 by Elsevier Science Inc.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 24 条
[1]   Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring: Comparison with conventional direct laryngoscopy [J].
Adachi, YU ;
Takamatsu, I ;
Watanabe, K ;
Uchihashi, Y ;
Higuchi, H ;
Satoh, T .
JOURNAL OF CLINICAL ANESTHESIA, 2000, 12 (07) :503-508
[2]   HEMODYNAMIC AND CATECHOLAMINE CHANGES AFTER INDUCTION OF ANESTHESIA WITH EITHER THIOPENTONE OR PROPOFOL WITH SUXAMETHONIUM [J].
BROSSY, MJ ;
JAMES, MFM ;
JANICKI, PK .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (05) :596-598
[3]   TOTAL IV ANESTHESIA WITH PROPOFOL AND THE LARYNGEAL MASK FOR ORTHOPEDIC-SURGERY [J].
DYER, RA ;
LLEWELLYN, RL ;
JAMES, MFM .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (02) :123-128
[4]   CARDIOVASCULAR-RESPONSES TO TRACHEAL INTUBATION - A COMPARISON OF DIRECT LARYNGOSCOPY AND FIBEROPTIC INTUBATION [J].
FINFER, SR ;
MACKENZIE, SIP ;
SADDLER, JM ;
WATKINS, TGL .
ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (01) :44-48
[5]   RETRACTED: CIRCULATORY RESPONSES TO LARYNGEAL MASK AIRWAY INSERTION OR TRACHEAL INTUBATION IN NORMOTENSIVE AND HYPERTENSIVE PATIENTS (Retracted article. See vol. 59, pg. 1177, 2012) [J].
FUJII, Y ;
TANAKA, H ;
TOYOOKA, H .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (01) :32-36
[6]   VALIDITY AND RELIABILITY OF LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION FOR MEASURING PLASMA-LEVELS OF NOREPINEPHRINE AND EPINEPHRINE IN MAN [J].
GOLDSTEIN, DS ;
FEUERSTEIN, G ;
IZZO, JL ;
KOPIN, IJ ;
KEISER, HR .
LIFE SCIENCES, 1981, 28 (05) :467-475
[7]  
HOUGHTON IT, 1993, ANAESTHESIA, V48, P965
[8]   COMPARISON OF CARDIOVASCULAR-RESPONSES TO AIRWAY MANAGEMENT - FIBEROPTIC INTUBATION USING A NEW ADAPTER, LARYNGEAL MASK INSERTION, OR CONVENTIONAL LARYNGOSCOPIC INTUBATION [J].
IMAI, M ;
MATSUMURA, C ;
HANAOKA, Y ;
KEMMOTSU, O .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (01) :14-18
[9]   HEMODYNAMIC AND CATECHOLAMINE RESPONSES TO INDUCTION OF ANESTHESIA AND TRACHEAL INTUBATION IN DIABETIC AND NONDIABETIC UREMIC PATIENTS [J].
KIRVELA, M ;
SCHEININ, M ;
LINDGREN, L .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (01) :60-65
[10]   A COMPARISON OF THE STRESS-RESPONSE TO LARYNGOSCOPY - THE MACINTOSH VERSUS THE MCCOY BLADE [J].
MCCOY, EP ;
MIRAKHUR, RK ;
MCCLOSKEY, BV .
ANAESTHESIA, 1995, 50 (11) :943-946