The pulse length-dependence of inertial cavitation dose and hemolysis

被引:131
作者
Chen, WS
Brayman, AA
Matula, TJ
Crum, LA
Miller, MW
机构
[1] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98195 USA
[2] Univ Rochester, Sch Med & Dent, Dept Obstet & Gynecol, Rochester, NY 14642 USA
关键词
inertial cavitation; broadband noise; active cavitation detection; passive cavitation detection; microbubbles; ultrasound contrast agent; Optison (R); Albunex (R); bioeffect; hemolysis;
D O I
10.1016/S0301-5629(03)00029-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Gas-based ultrasound (US) contrast agents increase erythrocyte sonolysis, presumably via enhancing inertial cavitation (IQ activity. The amount of IC activity (IC "dose") and hemolysis generated by exposure to 1.15 MHz US were examined with different US pulse lengths, but with the same delivered acoustic energy, for Optison(R) and Albunex(R). The hypotheses were that 1. at longer pulse lengths, IC would generate more bubbles that could nucleate additional IC activity; 2. if the interval between pulse pairs were short enough for the next pulse to hit derivative bubbles before their dissolution, more IC could be induced; and 3. hemolysis would be proportional to IC activity. Two types of studies were performed. In the first, bubble generation after each burst of IC activity was quantified using an active cavitation detector (ACD), for different pulse lengths (5, 10, 20, 30, 50, 100 or 200 cycles), but the same pressure level (3 MPa) and total "on" time (173.16 ms). Low concentrations of either Optison(R) or Albunexg were added into the tank with high-intensity and interrogating transducers orthogonal to each other. For pulse lengths > 100 cycles, and pulse repetition intervals < 5 ms, a "cascade" effect (explosive bubble generation) was observed. In the second, IC was measured by passive detection methods. IC dose and hemolysis were determined in whole blood samples at a pressure level (3 MPa) and interpulse interval (5 ms) that induced the "cascade" effect. Each blood sample was mixed with the same number of contrast microbubbles (Optison(R) similar to 0.3 v/v % and Albunex(R) - 0.5 v/v %), but exposed to different pulse lengths (5, 10, 20, 30, 50, 100 or 200 cycles). With Optison(R), up to 60% hemolysis was produced with long pulses (100 and 200 cycles), compared with < 10% with short pulses (5 and 10 cycles). Albunex(R) generated considerably less IC activity and hemolysis. The r(2) value was 0.99 for the correlation between hemolysis and IC dose. High pulse-repetition frequency (PRF) (500 Hz) generated more hemolysis than the low PRF (200 Hz) at 3 MPa. All experimental results could be explained by the dissolution times of IC-generated bubbles. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:739 / 748
页数:10
相关论文
共 18 条
[1]   THRESHOLDS FOR CAVITATION PRODUCED IN WATER BY PULSED ULTRASOUND [J].
ATCHLEY, AA ;
FRIZZELL, LA ;
APFEL, RE ;
HOLLAND, CK ;
MADANSHETTY, S ;
ROY, RA .
ULTRASONICS, 1988, 26 (05) :280-285
[2]   Sonolysis of Albunex®-supplemented, 40% hematocrit human erythrocytes by pulsed 1-MHz ultrasound:: Pulse number, pulse duration and exposure vessel rotation dependence [J].
Brayman, AA ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02) :307-314
[3]   Hemolysis of albunex-supplemented, 40% hematocrit human erythrocytes in vitro by 1-MHz pulsed ultrasound: Acoustic pressure and pulse length dependence [J].
Brayman, AA ;
Azadniv, M ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :927-938
[4]   Hemolysis of 40% hematocrit, Albunex(R)-supplemented human erythrocytes by pulsed ultrasound: Frequency, acoustic, pressure and pulse length dependence [J].
Brayman, AA ;
Strickler, PL ;
Luan, H ;
Barned, SL ;
Raeman, CH ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1237-1250
[5]   Thresholds for inertial cavitation in Albunex suspensions under pulsed ultrasound conditions [J].
Chang, PP ;
Chen, WS ;
Mourad, PD ;
Poliachik, SL ;
Crum, LA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (01) :161-170
[6]   The disappearance of ultrasound contrast bubbles: Observations of bubble dissolution and cavitation nucleation [J].
Chen, WS ;
Matula, TJ ;
Crum, LA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (06) :793-803
[7]   PULSED ENHANCEMENT OF ACOUSTIC CAVITATION - A POSTULATED MODEL [J].
CIARAVINO, V ;
FLYNN, HG ;
MILLER, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) :159-166
[8]   Study of ultrasonic contrast agents using a dual-frequency band technique [J].
Deng, CX ;
Lizzi, FL ;
Kalisz, A ;
Rosado, A ;
Silverman, RH ;
Coleman, DJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05) :819-831
[9]   In vitro measurements of inertial cavitation thresholds in human blood [J].
Deng, CX ;
Xu, QH ;
Apfel, RE ;
Holland, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :939-948
[10]  
Drabkin DL, 1932, J BIOL CHEM, V98, P719