Theoretical and experimental study on characteristics of a novel silica gel-water chiller under the conditions of variable heat source temperature

被引:52
作者
Di, J. [1 ]
Wu, J. Y. [1 ]
Xia, Z. Z. [1 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2007年 / 30卷 / 03期
关键词
chiller; adsorption system; water; silica gel; modelling; operation; transient; experiment; performance; COP;
D O I
10.1016/j.ijrefrig.2006.07.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a transient model of a silica gel-water adsorption chiller, which is developed in Shanghai Jiao Tong University (SJTU), is developed in order to simulate the evaporating, condensing, and adsorption temperature. Furthermore, this model is verified by a series of experiments. The theoretical studies and experimental data show that the coefficient of performance (COP) is influenced significantly by the variation rates of the heat source temperatures. The results also show that when this chiller is driven by solar energy, a buffer tank should be adopted in the system in order to get better performance when solar insolation is low, and should not be utilized when solar insolation is high, otherwise low COP will be gotten for the reason of the consumption of high electric energy. (c) 2006 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:515 / 526
页数:12
相关论文
共 17 条
[1]   A four-bed mass recovery adsorption refrigeration cycle driven by low temperature waste/renewable heat source [J].
Alam, KCA ;
Akahira, A ;
Hamamoto, Y ;
Akisawa, A ;
Kashiwagi, T .
RENEWABLE ENERGY, 2004, 29 (09) :1461-1475
[2]  
Boelman EC, 1995, ASHRAE TRAN, V101, P358
[3]   Modeling the performance of two-bed, silica gel-water adsorption chillers [J].
Chua, HT ;
Ng, KC ;
Malek, A ;
Kashiwagi, T ;
Akisawa, A ;
Saha, BB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (03) :194-204
[4]   Multi-bed regenerative adsorption chiller - improving the utilization of waste heat and reducing the chilled water outlet temperature fluctuation [J].
Chua, HT ;
Ng, KC ;
Malek, A ;
Kashiwagi, T ;
Akisawa, A ;
Saha, BB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02) :124-136
[5]   Entropy generation analysis of two-bed, silica gel-water, non-regenerative adsorption chillers [J].
Chua, HT ;
Ng, KC ;
Malek, A ;
Kashiwagi, T ;
Akisawa, A ;
Saha, BB .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (12) :1471-1477
[6]   PERFORMANCE LIMITATIONS OF ADSORPTION CYCLES FOR SOLAR COOLING [J].
CRITOPH, RE .
SOLAR ENERGY, 1988, 41 (01) :21-31
[7]  
KAMIL K, 2000, RENEW ENERG, V21, P79
[8]   Waste heat driven dual-mode, multi-stage, multi-bed regenerative adsorption system [J].
Saha, BB ;
Koyama, S ;
Kashiwagi, T ;
Akisawa, A ;
Ng, KC ;
Chua, HT .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07) :749-757
[9]   Performance evaluation of a low-temperature waste heat driven multi-bed adsorption chiller [J].
Saha, BB ;
Koyama, S ;
Lee, JB ;
Kuwahara, K ;
Alam, KCA ;
Hamamoto, Y ;
Akisawa, A ;
Kashiwagi, T .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2003, 29 (08) :1249-1263
[10]   Solar/waste heat driven two-stage adsorption chiller: the prototype [J].
Saha, BB ;
Akisawa, A ;
Kashiwagi, T .
RENEWABLE ENERGY, 2001, 23 (01) :93-101