A study of the diagnostic accuracy and reliability of the scoliometer and Adam's forward bend test

被引:158
作者
Côté, P
Kreitz, BG
Cassidy, JD
Dzus, AK
Martel, J
机构
[1] Univ Saskatchewan, Dept Phys Med & Rehabil, Inst Hlth & Outcomes Res, Saskatoon, SK, Canada
[2] Univ Saskatchewan, Dept Surg, Saskatoon, SK, Canada
关键词
Adam's forward bend test; diagnosis; idiopathic scoliosis; reliability; scoliometer; validity;
D O I
10.1097/00007632-199804010-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Study of the diagnostic accuracy and interexaminer reliability of scoliosis diagnostic tests. Objectives. To estimate the sensitivity, specificity, and predictive value of the Scoliometer (National Scoliosis Foundation, Watertown, MA) and Adam's forward bend test in diagnosing scoliosis, and to determine the interexaminer reliability of the Scoliometer and Adam's forward bend test. Summary of Background Data, Exposure to diagnostic radiation in patients with adolescent idiopathic scoliosis may result in a small but significant increase in cancer rates. The full-spine radiographic examination remains the standard procedure for the assessment of scoliosis. There is a need for a valid and reliable noninvasive test to assess scoliosis. Methods. Two examiners independently assessed 105 patients presenting to a scoliosis clinic for trunk asymmetry with Adam's forward bend test and axial trunk rotation with the Scoliometer. The Cobb method served as the gold standard. Results, The interexaminer agreement for the Scoliometer is excellent in the thoracic spine and substantial in the lumbar spine. The interexaminer measurement error shows poor precision for thoracic and lumbar Scoliometer measurements. The interexaminer agreement for Adam's forward bend test is substantial in the thoracic spine and poor in the lumbar spine. Adam's forward bend test is more sensitive than the Scoliometer in detecting thoracic curves measuring 20 degrees or more by the Cobb method. Receiver operating characteristic curve analysis suggests that the use of the Scoliometer marginally improves the ability of diagnosing a scoliosis in the thoracic spine. Conclusions. The Scoliometer and Adam's forward bend tests have adequate interexaminer reliability for the assessment of thoracic curves. The Scoliometer has better interexaminer agreement in the lumbar spine. However, the Scoliometer has a high level of interexaminer measurement error that limits its use as an outcome instrument. Because Adam's forward bend test is more sensitive than the Scoliometer, the authors believe that it remains the best noninvasive clinical test to evaluate scoliosis.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 34 条
[1]
VALIDITY AND RELIABILITY TESTING OF THE SCOLIOMETER [J].
AMENDT, LE ;
AUSEELLIAS, KL ;
EYBERS, JL ;
WADSWORTH, CT ;
NIELSEN, DH ;
WEINSTEIN, SL .
PHYSICAL THERAPY, 1990, 70 (02) :108-117
[2]
[Anonymous], STATISTICIAN
[3]
ARMSTRONG GD, 1981, NURS RES, V30, P314
[4]
INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[5]
BARWELL RG, 1981, LANCET, V2, P863
[6]
Bland M., 1987, INTRO MED STAT, P276
[7]
AN OBJECTIVE CRITERION FOR SCOLIOSIS SCREENING [J].
BUNNELL, WP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09) :1381-1387
[8]
THE LOGISTIC MODELING OF INTEROBSERVER AGREEMENT [J].
COUGHLIN, SS ;
PICKLE, LW ;
GOODMAN, MT ;
WILKENS, LR .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1992, 45 (11) :1237-1241
[9]
A MODEL FOR ASSESSING THE SENSITIVITY AND SPECIFICITY OF TESTS SUBJECT TO SELECTION BIAS - APPLICATION TO EXERCISE RADIONUCLIDE VENTRICULOGRAPHY FOR DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
ROZANSKI, A ;
FORRESTER, JS ;
MORRIS, D ;
POLLOCK, BH ;
STANILOFF, HM ;
BERMAN, DS ;
SWAN, HJC .
JOURNAL OF CHRONIC DISEASES, 1986, 39 (05) :343-355
[10]
CLINICAL EPISTEMOLOGY OF SENSITIVITY AND SPECIFICITY - DISSENT [J].
DIAMOND, GA .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1992, 45 (01) :9-13