Dual-energy x-ray absorptiometry: fat estimation errors due to variation in soft tissue hydration

被引:157
作者
Pietrobelli, A
Wang, ZM
Formica, C
Heymsfield, SB
机构
[1] Columbia Univ, St Lukes Roosevelt Hosp, Coll Phys & Surg, Obes Res Ctr, New York, NY 10025 USA
[2] Helen Hayes Hosp, Regional Bone Ctr, W Haverstraw, NY 10993 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM | 1998年 / 274卷 / 05期
关键词
body composition; physical model; fluid compartments;
D O I
10.1152/ajpendo.1998.274.5.E808
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) is rapidly gaining acceptance as a reference method for analyzing body composition. An important and unresolved concern is whether and to what extent variation in soft tissue hydration causes errors in DXA fat estimates. The present study aim was to develop and validate a DXA physical hydration model, and then to apply this model by simulating errors arising from hypothetical overhydration states. The DXA physical hydration model was developed by first linking biological substance elemental content with photon attenuation. The validated physical model was next extended to describe photon attenuation changes anticipated when predefined amounts of two known composition components are mined, as would occur when overhydration develops. Two overhydration models were developed in the last phase of study, formulated on validated physical models, and error was simulated for fluid surfeit states. Results indicate that systematic errors in DXA percent fat arise with added fluids when fractional masses are varied as a percentage of combined fluid + soft tissue mass. Three independent determinants of error magnitude were established: elemental content of overhydration fluid, fraction of combined fluid + soft tissue as overhydration fluid, and initial soft tissue composition. Small but systematic and predictable errors in DXA soft tissue composition analysis thus: can arise with fluid balance changes.
引用
收藏
页码:E808 / E816
页数:9
相关论文
共 47 条
[41]  
SPRAWLS P, 1977, PHYSICAL PRINCIPLES
[42]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE MEASUREMENT OF BONE AND SOFT-TISSUE COMPOSITION [J].
TOTHILL, P .
CLINICAL NUTRITION, 1995, 14 (05) :263-268
[43]  
WALLACE GF, 1981, ANAL METHODS INDUCTI
[44]   SYSTEMATIC ORGANIZATION OF BODY-COMPOSITION METHODOLOGY - AN OVERVIEW WITH EMPHASIS ON COMPONENT-BASED METHODS [J].
WANG, ZM ;
HESHKA, S ;
PIERSON, RN ;
HEYMSFIELD, SB .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (03) :457-465
[45]   THE 5-LEVEL MODEL - A NEW APPROACH TO ORGANIZING BODY-COMPOSITION RESEARCH [J].
WANG, ZM ;
PIERSON, RN ;
HEYMSFIELD, SB .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (01) :19-28
[46]   MEASURED ATTENUATION COEFFICIENTS AT LOW PHOTON ENERGIES (9.88-59.32 KEV) FOR 44 MATERIALS AND TISSUES [J].
WHITE, DR ;
PEAPLE, LHJ ;
CROSBY, TJ .
RADIATION RESEARCH, 1980, 84 (02) :239-252
[47]   Influence of changes in peritoneal fluid on body-composition measurements by dual-energy X-ray absorptiometry in patients receiving continuous ambulatory peritoneal dialysis [J].
Woodrow, G ;
Oldroyd, B ;
Turney, JH ;
Smith, MA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (02) :237-241