Fracture toughness and hardness evaluation of three pressable all-ceramic dental materials

被引:141
作者
Albakry, M
Guazzato, M
Swain, MV
机构
[1] Univ Sydney, Fac Dent, Biomat Sci Res Unit, Natl Innovat Ctr, Eveleigh, NSW 1430, Australia
[2] Univ Sydney, Fac Engn, Dept Aerosp Mech & Mechatron Engn, Sydney, NSW 2006, Australia
关键词
fracture toughness; hardness; lithium disilicate; leucite; X-ray diffraction; indentation strength; indentation fracture;
D O I
10.1016/S0300-5712(03)00025-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study evaluates the fracture toughness and hardness of three pressable all-ceramic materials: IPS-Empress, Empress 2 and an experimental. ceramic material.. Methods. Fifteen discs and 15 bars per material were prepared. Fracture toughness was measured with two different techniques: indentation fracture and indentation strength. During the indentation fracture tests the hardness of each material. was also measured. Statistical significance among groups of population was studied using one-way Anova and Tukey's multiple comparison tests. Results. Fracture toughness results using the indentation strength technique (with three-point bending and biaxial. flexure tests) were: IPS-Empress (1.39 (SD 0.3) and 1.32 (SD 0.3)); Empress 2 (3.14 (SD 0.5) and 2.50 (SD 0.3)) MPa (.) m(1/2); and the experimental ceramic (3.32 (SD 0.6) and 2.43 (SD 0.3)) MPa (.) m(1/2). The indentation fracture technique generated orthogonal cracks of different lengths for Empress 2 and the experimental ceramic, whether perpendicular or parallel to the lithium disiticate elongated crystals. Thus, two values were reported: Empress 2 (1.5 (SD 0.2) and 1.16 (SD 0.2)) MPa (.) am(1/2) and the experimental ceramic (1.67 (SD 0.3) and 1.15 (SD 0.15)) MPa (.) m(1/2). The IPS-Empress indentation fracture result was 1.26 (SD 0.1). The hardness results were: 6.6, 5.3 and 5.5 GPa for IPS-Empress, Empress 2 and the experimental ceramic, respectively. Conclusions. No significant differences in fracture toughness and hardness results were found between Empress 2 and the experimental ceramic (P > 0.05 ANOVA). Both materials exhibited fracture toughness anisotropy following pressing. They demonstrated improved fracture toughness and reduced hardness compared with IPS-Empress P < 0.05(ANOVA), which should be beneficial for clinical applications. (C) 2003 Elsevier Science Ltd. ALL rights reserved.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 27 条
[1]  
ALBAKRY M, 2003, IN PRESS J PROSTHETI
[2]  
[Anonymous], 1995, 6872 ISO
[3]  
[Anonymous], 1999, C132799 ASTM
[4]   A CRITICAL-EVALUATION OF INDENTATION TECHNIQUES FOR MEASURING FRACTURE-TOUGHNESS .1. DIRECT CRACK MEASUREMENTS [J].
ANSTIS, GR ;
CHANTIKUL, P ;
LAWN, BR ;
MARSHALL, DB .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1981, 64 (09) :533-538
[5]  
Anusavice K J, 1997, Gen Dent, V45, P30
[6]  
ASTM, 1996, F39478 ASTM
[7]  
ATKINSON DIH, 1977, J MATER SCI, P443
[8]   FRACTURE-TOUGHNESS ANISOTROPY OF A HOT-PRESSED AL2O3/SICW COMPOSITE [J].
BREDER, K ;
GIANNAKOPOULOS, AE ;
ZENG, K ;
ROWCLIFFE, D .
JOURNAL OF MATERIALS SCIENCE LETTERS, 1990, 9 (09) :1085-1086
[9]   The biaxial flexural strength of two pressable ceramic systems [J].
Cattell, MJ ;
Knowles, JC ;
Clarke, RL ;
Lynch, E .
JOURNAL OF DENTISTRY, 1999, 27 (03) :183-196
[10]   A CRITICAL-EVALUATION OF INDENTATION TECHNIQUES FOR MEASURING FRACTURE-TOUGHNESS .2. STRENGTH METHOD [J].
CHANTIKUL, P ;
ANSTIS, GR ;
LAWN, BR ;
MARSHALL, DB .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1981, 64 (09) :539-543