Clinical and angiographic outcome of patients with mild coronary lesions treated with balloon angioplasty or coronary stenting - Implications for mechanical plaque sealing

被引:35
作者
Mercado, N
Maier, W
Boersma, E
Bucher, C
de Valk, V
O'Neill, WW
Gersh, BJ
Meier, B
Serruys, PW
Wijns, W
机构
[1] Erasmus Univ, Hosp Dijkzigt, Ctr Thorax, Dept Cardiol,Clin Epidemiol Unit, NL-3015 GD Rotterdam, Netherlands
[2] Univ Zurich Hosp, Dept Cardiol, CH-8091 Zurich, Switzerland
[3] William Beaumont Hosp, Div Cardiol, Royal Oak, MI 48072 USA
[4] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[5] Univ Hosp Bern, Swiss Cardiovasc Ctr Bern, CH-3010 Bern, Switzerland
[6] Onze Lieve Vrouwe Ziekenhuis, Ctr Cardiovasc, Aalst, Belgium
关键词
balloon angioplasty; coronary stenting; plaque sealing;
D O I
10.1016/S0195-668X(02)00422-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To investigate the clinical and angiographic outcome of patients with mild coronary lesions treated with balloon angioplasty or coronary stenting (coronary plaque seating, i.e. dilatation of angiographically non-significant lesions) compared to moderate and severe stenoses. Methods and results Patients with chronic stable angina and a single de novo lesion in a native coronary vessel scheduled to undergo percutaneous coronary intervention (PCI) were selected from 14 different studies. Off-line analysis of angiographic outcomes was assessed in all patients using identical and standardised methods of data acquisition, analysis and definitions. Clinical endpoints were adjudicated by independent clinical events committees. All quantitative coronary angiographic (QCA) analyses were performed in the same core laboratory. Stenosis severity prior to PCI was categorised into three groups: <50% diameter stenosis (DS), 50-99%DS and >99%DS pre. A total of 3812 patients were included in this study; 1484 patients (39%) were successfully treated with balloon angioplasty (BA) only and stented angioplasty was performed in 2328 patients (61%). One-year mortality and rate of non-fatal myocardial infarction (MI) (Kaplan-Meier) did not differ between BA and stented angioplasty for any of the stenosis severity categories. Following BA, the combined event rate (death and non-fatal MI) was 4.8, 4.6 and 0% in the <50, 50-99 and >99%DS categories, respectively. Following stented angioplasty, the combined event rate was 3.1, 4.4 and 4.8% in the same categories. The need for repeat revascularisation corrected for stenosis severity in the Cox proportional-hazards regression model was reduced by 20% after stented angioplasty (hazard ratio (HR) 0.80, 95% Cl 0.69-0.93). Conclusion The concept of plaque seating is appealing from the theoretical point of view. However, with current technology, plaque seating cannot prevent death and future non-fatal Mis in the long-term because 1-year event rates after PCI of non-significant stenoses remain unacceptably elevated when compared with the estimated 1-year probability of a non-fatal MI in lesions with a <50%DS. Moreover, major adverse cardiac events at 1-year after PCI are not directly related to the degree of pre-procedural stenosis severity. (C) 2003 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:543 / 553
页数:11
相关论文
共 33 条
[21]  
2-T
[22]   Does angiography six months after coronary intervention influence management and outcome? [J].
Ruygrok, PN ;
Melkert, R ;
Morel, MAM ;
Ormiston, JA ;
Bär, FW ;
Fernandez-Avilès, F ;
Suryapranata, H ;
Dawkins, KD ;
Hanet, C ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (05) :1507-1511
[23]   A randomized placebo-controlled trial of fluvastatin for prevention of restenosis after successful coronary balloon angioplasty - Final results of the fluvastatin angiographic restenosis (FLARE) trial [J].
Serruys, PW ;
Foley, DP ;
Jackson, G ;
Bonnier, H ;
Macaya, C ;
Vrolix, M ;
Branzi, A ;
Shepherd, J ;
Suryapranata, H ;
de Feyter, PJ ;
Melkert, R ;
van Es, GA ;
Pfister, PJ .
EUROPEAN HEART JOURNAL, 1999, 20 (01) :58-69
[24]   Heparin-coated Palmaz-Schatz stents in human coronary arteries - Early outcome of the Benestent-II pilot study [J].
Serruys, PW ;
Emanuelsson, H ;
vanderGiessen, W ;
Lunn, AC ;
Kiemeney, F ;
Macaya, C ;
Rutsch, W ;
Heyndrickx, G ;
Suryapranata, H ;
Legrand, V ;
Goy, JJ ;
Materne, P ;
Bonnier, H ;
Morice, MC ;
Fajadet, J ;
Belardi, J ;
Colombo, A ;
Garcia, E ;
Ruygrok, P ;
deJaegere, P ;
Morel, MA .
CIRCULATION, 1996, 93 (03) :412-422
[25]   Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II) [J].
Serruys, PW ;
van Hout, B ;
Bonnier, H ;
Legrand, V ;
Garcia, E ;
Macaya, C ;
Sousa, E ;
van der Giessen, W ;
Colombo, A ;
Seabra-Gomes, R ;
Kiemeneij, F ;
Ruygrok, P ;
Ormiston, J ;
Emanuelsson, H ;
Fajadet, J ;
Haude, M ;
Klugmann, S ;
Morel, MA .
LANCET, 1998, 352 (9129) :673-681
[26]   The TRAPIST Study - A multicentre randomized placebo controlled clinical trial of trapidil for prevention of restenosis after coronary stenting, measured by 3-D intravascular ultrasound [J].
Serruys, PW ;
Foley, DP ;
Pieper, M ;
Kleijne, JA ;
de Feyter, PJ .
EUROPEAN HEART JOURNAL, 2001, 22 (20) :1938-1947
[27]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[28]  
Serruys PW, 1998, J INVASIVE CARDIOL, V10, p20B
[29]   Thermal heterogeneity within human atherosclerotic coronary arteries detected in vivo - A new method of detection by application of a special thermography catheter [J].
Stefanadis, C ;
Diamantopoulos, L ;
Vlachopoulos, C ;
Tsiamis, E ;
Dernellis, J ;
Toutouzas, K ;
Stefanadi, E ;
Toutouzas, P .
CIRCULATION, 1999, 99 (15) :1965-1971
[30]  
Suryapranata Harry, 2000, Int J Cardiovasc Intervent, V3, P21