Spectral reflectance of silicon photodiodes

被引:49
作者
Haapalinna, A [1 ]
Karha, P [1 ]
Ikonen, E [1 ]
机构
[1] Helsinki Univ Technol, Metrol Res Inst, FIN-02015 HUT, Finland
来源
APPLIED OPTICS | 1998年 / 37卷 / 04期
关键词
D O I
10.1364/AO.37.000729
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A precision spectrometer was used to measure the spectral reflectance of a silicon photodiode over the wavelength range from 250 to 850 nm. The results were compared with the corresponding values predicted by a model based on thin-film Fresnel formulas and the known refractive indices of silicon and silicon dioxide. The good agreement at the level of 2 x 10(-3) in the visible wavelength range verifies that the reflection model can be used for accurate extrapolation of the spectral reflectance and responsivity of silicon photodiode devices. In addition, characterization of the photodiode reflectance in the ultraviolet region improves the accuracy of the spectral irradiance measurements when filter radiometers based on trap detectors are used. (C) 1998 Optical Society of America.
引用
收藏
页码:729 / 732
页数:4
相关论文
共 15 条
[1]  
BORN M, 1965, PRINCIPLES OPTICS, P40
[2]   The NIST detector-based luminous intensity scale [J].
Cromer, CL ;
Eppeldauer, G ;
Hardis, JE ;
Larason, TC ;
Ohno, Y ;
Parr, AC .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (02) :109-132
[3]   TRAP DETECTORS AND THEIR PROPERTIES [J].
FOX, NP .
METROLOGIA, 1991, 28 (03) :197-202
[4]   Realization of a scale of absolute spectral response using the national institute of standards and technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Cromer, CL .
APPLIED OPTICS, 1996, 35 (22) :4392-4403
[5]  
HSIA JJ, 1994, APPL OPTICS, V19, P1268
[6]  
Jellison G. E. Jr., 1992, Optical Materials, V1, P41, DOI 10.1016/0925-3467(92)90015-F
[7]   A METHOD OF REALIZING SPECTRAL IRRADIANCE BASED ON AN ABSOLUTE CRYOGENIC RADIOMETER [J].
JOHNSON, BC ;
CROMER, CL ;
SAUNDERS, RD ;
EPPELDAUER, G ;
FOWLER, J ;
SAPRITSKY, VI ;
DEZSI, G .
METROLOGIA, 1993, 30 (04) :309-315
[8]  
KARHA P, 1995, OPT ENG, V34, P2611, DOI 10.1117/12.208095
[9]   Detector-based calibration method for high-accuracy solar UV measurements [J].
Karha, P ;
Visuri, R ;
Leszczynski, K ;
Manoochehri, F ;
Jokela, K ;
Ikonen, E .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1996, 64 (02) :340-343
[10]   Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range [J].
Karha, P ;
Toivanen, P ;
Manoochehri, F ;
Ikonen, E .
APPLIED OPTICS, 1997, 36 (34) :8909-8918