The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

被引:52
作者
Chen, Ligang [1 ]
Ding, Lan [1 ]
Jin, Haiyan [1 ]
Song, Daqian [1 ]
Zhang, Huarong [1 ]
Li, Jiantao [1 ]
Zhang, Kun [1 ]
Wang, Yutang [1 ]
Zhang, Hanqi [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
关键词
dynamic microwave-assisted extraction; solid-phase extraction; high-performance liquid chromatography (HPLC); on-line determination; organochlorine pesticides; grain;
D O I
10.1016/j.aca.2007.03.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min(-1). The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g(-1). The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required. circle star 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 48 条
[21]   Methods for selective determination of persistent organochlorine pesticide residues in water and sediments by capillary gas chromatography and electron-capture detection [J].
Fatoki, OS ;
Awofolu, RO .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :225-236
[22]   Accelerated solvent extraction: An evaluation for screening of soils for selected US EPA semivolatile organic priority pollutants [J].
Fisher, JA ;
Scarlett, MJ ;
Stott, AD .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (04) :1120-1127
[23]   MICROWAVE EXTRACTION - A NOVEL SAMPLE PREPARATION METHOD FOR CHROMATOGRAPHY [J].
GANZLER, K ;
SALGO, A ;
VALKO, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :299-306
[24]   Screening, optimization and validation of microwave-assisted extraction for the determination of persistent organochlorine pesticides [J].
Gfrerer, M ;
Lankmayr, E .
ANALYTICA CHIMICA ACTA, 2005, 533 (02) :203-211
[25]   ONLINE SAMPLE PREPARATION FOR THE DETERMINATION OF RIBOFLAVIN AND FLAVIN MONONUCLEOTIDES IN FOODSTUFFS [J].
GREENWAY, GM ;
KOMETA, N .
ANALYST, 1994, 119 (05) :929-935
[26]   Comparisons of Soxhlet extraction, pressurized liquid extraction, supercritical fluid extraction and subcritical water extraction for environmental solids: recovery, selectivity and effects on sample matrix [J].
Hawthorne, SB ;
Grabanski, CB ;
Martin, E ;
Miller, DJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :421-433
[27]   Determination of pesticides and PCBs in honey by solid-phase extraction cleanup followed by gas chromatography with electron-capture and nitrogen-phosphorus detection [J].
Herrera, A ;
Pérez-Arquillué, C ;
Conchello, P ;
Bayarri, S ;
Lázaro, R ;
Yagüe, C ;
Ariño, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) :695-701
[28]   Dynamic approach based on iterative change of the flow direction for microwave-assisted leaching of cadmium and lead from plant prior to GF-AAS [J].
Herrera, MC ;
de Castro, MDL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (11) :1530-1533
[29]   Microwave assisted solvent extraction and coupled-column reversed-phase liquid chromatography with UV detection - Use of an analytical restricted-access-medium column for the efficient multi-residue analysis of acidic pesticides in soils [J].
Hogendoorn, EA ;
Huls, R ;
Dijkman, E ;
Hoogerbrugge, R .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :23-33
[30]   Feasibility study of ion-chromatography microwave assisted on-line species conversion hydride generation atomic absorption spectrometry for selenium speciation analysis of biological material [J].
Johansson, M ;
Bordin, G ;
Rodriguez, AR .
ANALYST, 2000, 125 (02) :273-279