Iterative threshold segmentation for PET target volume delineation

被引:78
作者
Drever, Laura
Roa, Wilson
McEwan, Alexander
Robinson, Don [1 ]
机构
[1] BC Canc Agcy, Dept Med Phys, Victoria, BC V8R 6V5, Canada
[2] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
[3] Cross Canc Inst, Dept Oncol Imaging, Edmonton, AB T6G 1Z2, Canada
关键词
PET; threshold segmentation; iterative; target volume;
D O I
10.1118/1.2712043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to create a rigorous method of segmenting PET images using an automated iterative technique. To this end a phantom study employing spherical targets was used to determine local (slice specific) threshold levels which produce correct cross-sections based on the contrast between target and background. Numerous target to background activity concentration ratios were investigated but found to have minimal effect in comparison to the influence of target size. Functions were fit to this data and used to construct an iterative threshold segmentation algorithm. In all cases this approach yielded convergence within ten iterations. Iterative threshold segmentation was applied using both an axial and tri-axial approach to the spherical targets and also to two irregularly shaped volumes. Of these two approaches, the tri-axial method proved less susceptible to image noise and better at dealing with partial volume effects at the interface between target and background. For comparative purposes, single thresholds of 28% and 40% were also applied to the spherical data sets. The tri-axial iterative method was found capable of delineating cross sections with areas greater than 250 mm 2 1 to within the maximum resolution possible (1 pixel width). Cross sections of less than 250 rum 2 in area were resolved by the tri-axial method to within 2 pixel widths of their true physical extent. Local contrast based iterative threshold segmentation shows promise as a method of rigorously delineating PET target volumes with good accuracy subject to the limitations imposed by the image resolution which currently characterizes this modality. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1253 / 1265
页数:13
相关论文
共 19 条
[1]  
Adam LE, 2001, J NUCL MED, V42, P1821
[2]  
Bar-Shalom R, 2003, J NUCL MED, V44, P1200
[3]   Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET [J].
Caldwell, CB ;
Mah, K ;
Skinner, M ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1381-1393
[4]  
Dimitrakopoulou-Strauss A, 2003, J NUCL MED, V44, P556
[5]  
ERDI EE, 1997, CANCER S80, V12, P2505
[6]   Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET) [J].
Erdi, YE ;
Rosenzweig, K ;
Erdi, AK ;
Macapinlac, HA ;
Hu, YC ;
Braban, LE ;
Humm, JL ;
Squire, OD ;
Chui, CS ;
Larson, SM ;
Yorke, ED .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) :51-60
[7]   CT and 18F-deoxyglucose (FDG) image fusion for optimization of conformal radiotherapy of lung cancers [J].
Giraud, P ;
Grahek, D ;
Montravers, F ;
Carette, MF ;
Deniaud-Alexandre, E ;
Julia, F ;
Rosenwald, JC ;
Cosset, JM ;
Talbot, JN ;
Housset, M ;
Touboul, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05) :1249-1257
[8]   Is there any future in radiotherapy planning without the use of PET: unraveling the myth... [J].
Gregoire, V .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (03) :261-263
[9]  
GROSU A, INT J RAD ONCOL BIOL, V56, P1450
[10]   Experience of PET for target localisation in radiation oncology [J].
Grosu, AL ;
Piert, M ;
Molls, M .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :18-32