An investigation of internal pressures in capillary flow injection systems

被引:12
作者
Spence, DM [1 ]
Crouch, SR [1 ]
机构
[1] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
capillary flow injection; internal pressures; peristaltic pumps; syringe pump; pressure-induced flow;
D O I
10.1016/S0003-2670(97)00593-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Results of an investigation of pressure drops in a capillary flow injection (CFI) system are presented. Peristaltic and syringe pumps were used to drive reagents through a manifold employing fused silica capillaries (75 mu m i.d.) as the reactor tubing. A comparison of pressure capabilities, baseline noise levels and reproducibility was performed. The maximum stable pressure for the peristaltic pump and syringe pump were 7.6 and 19.2 bar, respectively. The maximum stable pressures for the syringe pump varies with the inside diameter of the syringe. For the peristaltic pump, the percent relative standard deviation of the pressure drop was less than 2%. When no time was allowed for equilibration, the reproducibility of the syringe pump was between 6% and 10%. When equilibration time was allowed, however the reproducibility was also better than 2%. Reproducibility was also measured by using an enzyme catalyzed reaction with reaction periods as long as 242+/-1 s. Each pump showed baseline noise levels of less than 5 milliabsorbance units. Based on these observed values, practical considerations for designing CFI manifolds are also reported. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 14 条
[1]   ELECTROOSMOSIS - A RELIABLE FLUID PROPULSION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
DASGUPTA, PK ;
LIU, S .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1792-1798
[2]  
INGLE JD, 1988, SPECTROCHEMICAL ANAL, P141
[3]   ELECTROOSMOTICALLY PUMPED CAPILLARY FLOW-INJECTION ANALYSIS - VALVE-BASED INJECTION SYSTEMS AND SAMPLE THROUGHPUT [J].
LIU, SR ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1993, 283 (02) :739-745
[4]   FLOW-INJECTION ANALYSIS IN THE CAPILLARY FORMAT USING ELECTROOSMOTIC PUMPING [J].
LIU, SR ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1992, 268 (01) :1-6
[5]  
PATTON CJ, 1982, THESIS MICHIGAN STAT
[6]   GLUCOSE-OXIDASE AS AN ANALYTICAL REAGENT [J].
RABA, J ;
MOTTOLA, HA .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1995, 25 (01) :1-42
[7]  
RUZICKA J, 1983, ANAL CHEM, V55, P1040
[8]  
RUZICKA J, 1984, ANAL CHIM ACTA, V161, P1
[9]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd
[10]   Factors affecting zone variance in a capillary flow injection system [J].
Spence, DM ;
Crouch, SR .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :165-169