A single bit RF domain complex cross-correlation velocity estimator for color flow mapping

被引:1
作者
Brands, PJ [1 ]
Hoeks, APG [1 ]
Ledoux, LAF [1 ]
机构
[1] Univ Limburg, Cardiovasc Res Inst, Dept Biophys, NL-6200 MD Maastricht, Netherlands
关键词
flow mapping; flow velocity; mean frequency; one bit estimator; signal processing; ultrasound;
D O I
10.1177/016173469701900302
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper evaluates the performance of a one bit mean frequency estimator to estimate blood flow velocity for ultrasound color flow mapping. This one bit mean frequency estimator, referred to as BC3 estimator, is derived from the recently introduced complex cross-correlation model (C3M) employing the full dynamic data range. The C3M velocity estimator is not suitable for application in color flow mapping because of its high hardware complexity and associated computational load. The BC3 estimator estimates the mean blood flow velocity using only two complex cross-correlation coefficients. For this purpose the latter are computed by means of a complex one bit cross-correlation operation. Each sample of the RF signals is converted into an one bit representation based on the sign of the real and imaginary part of the RF samples. A full derivation and mathematical description of the BC3 estimator is presented. In addition, a thorough performance evaluation of the BC3 estimator in comparison with the full dynamic range C3M velocity estimator is carried out by means of signal simulations to document the effect of signal to noise ratio, sample frequency and bandwidth. For the specific simulation conditions considered the standard deviation of both estimators (C3M and BC3) is comparable. The bias of the BC3 estimator appears to be a function of velocity, while the full dynamic range C3M velocity estimator exhibits no bias. The simulation results are confirmed by evaluation of data from an in vivo measurement. Taking into account the low hardware complexity and computational load in combination with the achieved precision, it may be concluded that the BC3 estimator is well suited for implementation in color flow mapping. (C) 1997 Dynamedia, Inc.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 20 条
[1]   A radio frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound [J].
Brands, PJ ;
Hoeks, APG ;
Ledoux, LAF ;
Reneman, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :911-920
[2]   A COMPARISON METHOD FOR MEAN FREQUENCY ESTIMATORS FOR DOPPLER ULTRASOUND [J].
BRANDS, PJ ;
HOEKS, APG .
ULTRASONIC IMAGING, 1992, 14 (04) :367-386
[3]   VECTORIAL MEASUREMENT OF BLOOD VELOCITY BY MEANS OF ULTRASOUND [J].
DOTTI, D ;
LOMBARDI, R ;
PIAZZI, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (02) :219-225
[4]   VOLUMETRIC BLOOD-FLOW VIA TIME-DOMAIN CORRELATION - EXPERIMENTAL-VERIFICATION [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :176-189
[5]  
Ferrara KW, 1996, ULTRASOUND MED BIOL, V22, P293, DOI 10.1016/0301-5629(95)02060-8
[6]   A NEW WIDE-BAND SPREAD TARGET MAXIMUM-LIKELIHOOD ESTIMATOR FOR BLOOD VELOCITY ESTIMATION .1. THEORY [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :1-16
[7]  
FORSTER FK, 1978, ADV BIOENG, P113
[8]   FLOW VELOCITY PROFILE VIA TIME-DOMAIN CORRELATION ERROR ANALYSIS AND COMPUTER-SIMULATION [J].
FOSTER, SG ;
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :164-175
[9]   Improved estimation of low velocities in color Doppler imaging by adapting the mean frequency estimator to the clutter rejection filter [J].
Herment, A ;
Demoment, G ;
Dumee, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (09) :919-927
[10]   SUBSAMPLE VOLUME PROCESSING OF DOPPLER ULTRASOUND SIGNALS [J].
HOEKS, APG ;
BRANDS, PJ ;
ARTS, TGJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :953-965