A modular software system for computer-aided surgery and its first application in oral implantology

被引:37
作者
Birkfellner, W
Huber, K
Larson, A
Hanson, D
Diemling, M
Homolka, P
Bergmann, H
机构
[1] Univ Vienna, Dept Biomed Engn & Phys, Gen Hosp, A-1090 Vienna, Austria
[2] Mayo Clin, Biomed Imaging Resource, Rochester, MN 55901 USA
关键词
AVW; computer-aided surgery; oral implantology;
D O I
10.1109/42.870668
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Development of complex software applications in image guided therapy (IGT) is often complicated by the fact that providing basic functionality for image processing and user interaction from a graphical user interfaces (GUI) requires considerable manpower for software development. We present a programming environment that combines the high-level image processing library AVW, in-house developed patient-to-image registration procedures, and an interface to position measurement hardware. A specific application can be developed by using Tcl/Tk, a simple platform-independent scripting language, for SUI development, This environment was applied to developing VISIT, a navigation sg stem for computer-aided implant dentistry. VISIT is presented as a result of this paper. Parts of the development environment were made accessible to the public, Future work includes the implementation of video input for connecting ultrasound or fluoroscopy units. We conclude that our approach is well suited to accelerate the development of exploratory new applications of IGT.
引用
收藏
页码:616 / 620
页数:5
相关论文
共 18 条
[1]
[Anonymous], 3 DIMENSIONAL BIOMED
[2]
A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[3]
Birkfellner W, 1999, LECT NOTES COMPUT SC, V1679, P883
[4]
Calibration of tracking systems in a surgical environment [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Ewers, R ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :737-742
[5]
QUATERNION KINEMATIC AND DYNAMIC DIFFERENTIAL-EQUATIONS [J].
CHOU, JCK .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1992, 8 (01) :53-64
[6]
Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[7]
CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS [J].
HORN, BKP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04) :629-642
[8]
Lewine Donald, 1991, POSIX PROGRAMMERS GU
[9]
Ousterhout J. K., 1994, TCL TK TOOLKIT
[10]
Writing software for the clinic [J].
Rosen, II .
MEDICAL PHYSICS, 1998, 25 (03) :301-309