Amperometric microcell for enzyme activity measurements

被引:23
作者
Nagy, G
Xu, CX
Buck, RP
Lindner, E
Neuman, MR
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[3] Case Western Reserve Univ, Metrohlth Med Ctr, Dept Obstet & Gynecol, Cleveland, OH 44109 USA
关键词
D O I
10.1021/ac971221z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A small-volume cell was developed for enzyme activity measurements. The cell contained a detector chip, which was prepared using photolithographic and electrochemical techniques. The enzyme-catalyzed reaction takes place in a thin film inside the cell, and the concentration changes are followed in time with an amperometric detector. The combination of the thin-layer reaction medium and surface detection allows achievement of high sensitivity with very low sample volumes. The cell can be prepared as an inexpensive single-shot test device. The analytical performance of the cell was checked with several enzymes of clinical importance. Demonstration measurements were made with robust glucose oxidase. Then, an analytical procedure was worked out for the measurement of putrescine oxidase activity, an indicator for premature rupture of the amniotic membrane. Finally, two different reaction schemes were investigated for the activity determination of the myocardial infarction marker, creatine kinase.
引用
收藏
页码:2156 / 2162
页数:7
相关论文
共 24 条
[1]  
BANK CM, 1991, EUR J CLIN CHEM CLIN, V29, P743
[2]  
BLUM W, 1949, PRINCIPLES ELECTROPL, P382
[3]   MICROFABRICATION TECHNOLOGY OF FLEXIBLE MEMBRANE-BASED SENSORS FOR IN-VIVO APPLICATIONS [J].
BUCK, RP ;
COSOFRET, VV ;
LINDNER, E ;
UFER, S ;
MADARAS, MB ;
JOHNSON, TA ;
ASH, RB ;
NEUMAN, MR .
ELECTROANALYSIS, 1995, 7 (09) :846-851
[4]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[5]  
ELMFORS B, 1974, J OBSTET GYN BR COMM, V81, P361
[6]  
GAHL WA, 1982, OBSTET GYNECOL, V60, P297
[7]  
IVES DJG, 1961, REFERENCE ELECTRODES
[8]   FLEXIBLE (KAPTON-BASED) MICROSENSOR ARRAYS OF HIGH-STABILITY FOR CARDIOVASCULAR APPLICATIONS [J].
LINDNER, E ;
COSOFRET, VV ;
UFER, S ;
BUCK, RP ;
KUSY, RP ;
ASH, RB ;
NAGLE, HT .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1993, 89 (02) :361-367
[9]   Miniaturized biosensors employing electropolymerized permselective films and their use for creatinine assays in human serum [J].
Madaras, MB ;
Buck, RP .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3832-3839
[10]   Microfabricated amperometric creatine and creatinine biosensors [J].
Madaras, MB ;
Popescu, IC ;
Ufer, S ;
Buck, RP .
ANALYTICA CHIMICA ACTA, 1996, 319 (03) :335-345