Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS

被引:84
作者
Heitland, P [1 ]
Köster, HD [1 ]
机构
[1] Med Lab Bremen, D-28357 Bremen, Germany
关键词
D O I
10.1039/b410630j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper presents a method for the fast, simple and reliable routine determination of As, Ba, Be, Co, Cd, Cu, Cr, In, Li, Mn, Mo, Ni, Pb, Pt, Rh, Sb, Se, Sn, Tl, U, V, W and Zn in urine by inductively coupled plasma mass spectrometry (ICP-MS) with an octopole based collision cell. The complete method validation for all elements is described, including the evaluation of short- and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and external quality assurance. The urine samples were analysed directly after a 1/5 (v/v) dilution with 1% (v/v) nitric acid. The sample introduction system consisted of a robust Babington nebulizer for sample introduction into the ICP and a torch with an injector tube with an inner diameter of 2.5 mm. Combined with a low sample aspiration rate (0.4 ml min(-1)) these applied ICP operating conditions enable the analysis of 500 samples without clogging of the nebulizer and deposition of particles in the injector tube. Limits of detection are in the range 0.4 ng l(-1) (for U) to 143 ng l(-1) ( for Se) calculated to the undiluted urine. Spectral interferences from polyatomic ions were removed by adding 3.2 ml min(-1) helium ( for As, Ba, Cd, Cr, Cu, Mo, Mn, Ni, Rh, V, Zn) or 3.4 ml min(-1) hydrogen ( for Se) as collision gas. The analysis results of 63 real urine samples from non-exposed human subjects are presented. ICP-MS fitted with a collision cell enables the simultaneous determination of all 23 elements either in their essential concentration range or at concentration levels relevant for occupational and environmental health. For some elements ( Rh, Pt, W, Mn) most of the concentrations in urine are below the limit of quanti. cation, for other elements ( Li, Pb, Co, Tl Cu, Zn, Se) good agreement with previous studies was found, while for a further group of elements ( Be, Cr, Ni, Cd) new results or useful statistical data are presented.
引用
收藏
页码:1552 / 1558
页数:7
相关论文
共 46 条
[1]   Maternal and cord blood serum levels of zinc, copper, and iron in healthy pregnant Jordanian women [J].
Awadallah, SM ;
Abu-Elteen, KH ;
Elkarmi, AZ ;
Qaraein, SH ;
Salem, NM ;
Mubarak, MS .
JOURNAL OF TRACE ELEMENTS IN EXPERIMENTAL MEDICINE, 2004, 17 (01) :1-8
[2]  
Baselt RC., 2008, Disposition of Toxic Drugs and Chemicals in Man, V8
[3]   German Environmental Survey 1998 (GerES III): environmental pollutants in the urine of the German population [J].
Becker, K ;
Schulz, C ;
Kaus, S ;
Seiwert, M ;
Seifert, B .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2003, 206 (01) :15-24
[4]   Mass spectral interferences in the determination of trace levels of precious metals in human blood using quadrupole magnetic sector field and inductively coupled plasma mass spectrometry [J].
Begerow, J ;
Dunemann, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) :303-306
[5]   Determination of physiological noble metals in human urine using liquid-liquid extraction and Zeeman electrothermal atomic absorption spectrometry [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :277-283
[6]   Determination of physiological palladium and platinum levels in urine using double focusing magnetic sector field ICP-MS [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :427-429
[7]   New horizons in human biomonitoring of environmentally and occupationally relevant metals-sector-field ICP-MS versus electrothermal AAS [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :347-352
[8]   Long-term urinary platinum, palladium, and gold excretion of patients after insertion of noble-metal dental alloys [J].
Begerow, J ;
Neuendorf, J ;
Turfeld, M ;
Raab, W ;
Dunemann, L .
BIOMARKERS, 1999, 4 (01) :27-36
[9]   Determination of physiological palladium, platinum, iridium and gold levels in human blood using double focusing magnetic sector field inductively coupled plasma mass spectrometry [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :1095-1098
[10]  
BEGEROW J, 2001, ANAL HAZARDOUS SUBST, V7, P97