In vivo evaluation of a retrievable vena cava filter - The Dibie-Musset filter: Experimental results

被引:15
作者
Dibie, A [1 ]
Musset, D [1 ]
Heissler, M [1 ]
Fournet, JC [1 ]
Palau, R [1 ]
Laborde, F [1 ]
机构
[1] Inst Mutualiste Montsouris, Dept Cardiovasc, F-75013 Paris, France
关键词
embolism; pulmonary; venae cavae; filters; interventional procedures; experimental; in vivo studies;
D O I
10.1007/s002709900233
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate, in an animal model, the efficacy and safety of a 7 Fr percutaneous vena cava filter for temporary or permanent use. Methods: The Dibie-Musset (DM) filter is a wire preformed into a double-spiral shape with a spring effect. The experiment was performed in 15 adult sheep and consisted of the insertion of 45 filters, clot trapping tests, and filter retrieval. Follow-up in all sheep consisted of radiologic (abdominal radiograph, inferior vena cavogram, abdominal computed tomography), macroscopic, and microscopic examinations between days 8 and 386 after filter placement. Results: Of the 45 filters implanted in 15 sheep, 29 were retrieved between day 0 and day 15. Filtration efficiency was 100% for clots 4 x 4 x 20 mm. No longterm (1 year) side-effects were detectable, Microscopic examination of the vein wall showed only a dense intimal fibrosis without signs of acute inflammation at 1 year. Conclusion: These results support the efficiency and safety of the DM filter in an animal model.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 16 条
  • [1] CHAVAN A, 1993, Z KARDIOL, V82, P191
  • [2] DIBIE A, 1994, ARCH MAL COEUR VAISS, V87, P115
  • [3] EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER
    EPSTEIN, DH
    DARCY, MD
    HUNTER, DW
    COLEMAN, CC
    TADAVARTHY, SM
    MURRAY, PD
    CASTANEDAZUNIGA, WR
    AMPLATZ, K
    [J]. RADIOLOGY, 1989, 172 (01) : 105 - 110
  • [4] HEENAN SD, 1995, J INTERVENT RADIOL, V10, P111
  • [5] HOSAKA J, 1993, EUR RADIOL, V9, P177
  • [6] OPERATOR ERRORS DURING PERCUTANEOUS PLACEMENT OF VENA-CAVA FILTERS
    KAUFMAN, JA
    GELLER, SC
    RIVITZ, SM
    WALTMAN, AC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) : 1281 - 1287
  • [7] PRELIMINARY CLINICAL-EXPERIENCE WITH THE GUNTHER TEMPORARY INFERIOR VENA-CAVA FILTER
    MILLWARD, SF
    BORMANIS, J
    BURBRIDGE, BE
    MARKMAN, SJ
    PETERSON, RA
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (06) : 863 - 868
  • [8] A RETRIEVABLE NITINOL VENA-CAVA FILTER - EXPERIMENTAL AND INITIAL CLINICAL-RESULTS
    NAKAGAWA, N
    CRAGG, AH
    SMITH, TP
    CASTANEDA, F
    BARNHART, WH
    DEJONG, SC
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (03) : 507 - 512
  • [9] NEW RETRIEVABLE PERCUTANEOUS VENA-CAVA FILTER - EXPERIMENTAL IN-VITRO AND IN-VIVO EVALUATION
    NEUERBURG, J
    GUNTHER, RW
    RASSMUSSEN, E
    VORWERK, D
    TONN, K
    HANDT, S
    KUPPER, W
    HANSEN, JV
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) : 224 - 229
  • [10] Results of a multicenter study of the retrievable tulip vena cava filter: Early clinical experience
    Neuerburg, JM
    Gunther, RW
    Vorwerk, D
    Dondelinger, RF
    Jager, H
    Lackner, KJ
    Schild, HH
    Plant, GR
    Joffre, FG
    Schneider, PA
    Janssen, JHA
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 20 (01) : 10 - 16