Liquid chromatography for iothalamate in biological samples

被引:20
作者
Agarwal, R
Vasavada, N
Chase, SD
机构
[1] Indiana Univ, Indianapolis, IN 46202 USA
[2] VAMC, Indianapolis, IN 46202 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 785卷 / 02期
关键词
iothalamate;
D O I
10.1016/S1570-0232(02)00960-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have previously reported an iothalamate assay for the assessment of the glomerular filtration rate (GFR) that required a long column equilibration time and 22 min run time per sample. We now report a simpler assay that requires a run time of only 5.5 min and is more precise and accurate than the earlier technique. The mobile phase consisted of methanolacetonitrile-50 mM sodium monobasic phosphate (10:5:85, v/v) at pH 4.4, pumped at a rate of 1.5 ml/min on a C-18 reversed-phase column. Samples of plasma and urine were deproteinized with 1 volume of 4% perchloric acid or 9 volumes of 2% perchloric acid, respectively. No internal standard was used. The diode array detection system collected absorbance at 240 nm and the peak height areas of iothalamate were determined. The iothalamate peak appeared at 3.5 min. Detector response was linear over the range tested (10-2000 mug/ml). Within-run precision was <3% for both plasma and urine and accuracy was 96-102%. Between-day precision for plasma and urine analyses were <7%. The recovery of iothalamate in urine and plasma were 102% and 91%, respectively. There was excellent thermal and pH stability of iothalamate. No interference was found with para-amino hippuric acid (PAH) or N-acetyl PAH, which can be simultaneously assayed, if desired. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:345 / 352
页数:8
相关论文
共 16 条
  • [1] Agarwal R, 1998, J CHROMATOGR B, V705, P3
  • [2] ANDERSON DJ, 1989, CLIN CHEM, V35, P2152
  • [3] ACE inhibition or angiotensin receptor blockade: Impact on potassium in renal failure
    Bakris, GL
    Siomos, M
    Richardson, D
    Janssen, I
    Bolton, WK
    Hebert, L
    Agarwal, R
    Catanzaro, D
    [J]. KIDNEY INTERNATIONAL, 2000, 58 (05) : 2084 - 2092
  • [4] A NONRADIOACTIVE IOTHALAMATE AND P-AMINOHIPPURIC ACID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR SIMULTANEOUSLY MEASURING GLOMERULAR-FILTRATION RATE AND RENAL BLOOD-FLOW IN THE RAT
    BELL, RR
    BOMBARDT, PA
    DUCHARME, DW
    KOLAJA, GJ
    PACKWOOD, WH
    BOTHWELL, BE
    SATOH, PS
    [J]. BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (05) : 224 - 229
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE SIMULTANEOUS DETERMINATION OF IOTHALAMATE AND OMICRON-IODOHIPPURATE
    BOSCHI, S
    MARCHESINI, B
    [J]. JOURNAL OF CHROMATOGRAPHY, 1981, 224 (01): : 139 - 143
  • [6] THE ASSESSMENT OF METHODS OF MEASUREMENT
    CHINN, S
    [J]. STATISTICS IN MEDICINE, 1990, 9 (04) : 351 - 362
  • [7] PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE
    COCKCROFT, DW
    GAULT, MH
    [J]. NEPHRON, 1976, 16 (01) : 31 - 41
  • [8] Simultaneous determination of p-aminohippuric acid, acetyl-p-aminohippuric acid and iothalamate in human plasma and urine by high-performance liquid chromatography
    Dowling, TC
    Frye, RF
    Zemaitis, MA
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2): : 305 - 313
  • [9] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF IOTHALAMIC ACID IN HUMAN PLASMA AND URINE
    GASPARI, F
    MAINARDI, L
    RUGGENENTI, P
    REMUZZI, G
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (02): : 435 - 440
  • [10] LEVEY AS, 1988, ANNU REV MED, V39, P465, DOI 10.1146/annurev.med.39.1.465