Estimation of vessel flow and diameter during cerebral vasospasm using transcranial Doppler indices

被引:33
作者
Giller, CA [1 ]
Hatab, MR
Giller, AM
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Neurol Surg, Dallas, TX 75235 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Radiol, Dallas, TX 75235 USA
关键词
aneurysm; cerebral blood flow; cerebral blood vessels; subarachnoid hemorrhage; transcranial Doppler ultrasound; vasospasm;
D O I
10.1097/00006123-199805000-00077
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: An important limitation of transcranial Doppler (TCD) ultrasonography is its inability to directly measure blood flow or vessel diameter. To extend the ability of TCD ultrasonography, indices were derived from an intensity-weighted mean of the entire Doppler spectrum. The objective of this article is to test the behavior of these Indices under conditions of diameter constancy (hyper- and hypoventilation) and when vessel diameter decreases (vasospasm). METHODS: A flow index (FI) was calculated by averaging several heartbeats of spectral data and calculating the first spectral moment. An area index (Al) was defined as the FI divided by the mean velocity, motivated by the knowledge that vessel flow is the product of vessel diameter and mean velocity. To test the FI and the AI under conditions of diameter constancy, middle cerebral artery Doppler signals were obtained from 20 patients during conditions of hypercarbia, hypocarbia, and normocarbia. To test the ability of these indices to evaluate a decrease in vessel diameter, signals from 41 sites on 23 arteries were obtained from patients who underwent both TCD and angiographic studies on two separate occasions after the occurrence of subarachnoid hemorrhage. The changes in the AI were compared with the arterial diameters measured from angiograms. RESULTS: The FI was proportional to the mean velocity in the cohort of healthy patients (r = 0.97). The AI changed by less than 3% in the same cohort. The AI predicted the direction of the diameter change in all vessels showing angiographic changes in area. Changes in the AI and the measured angiographic changes in cross-sectional areas were correlated (overall, r = 0.90; with two outlines removed, r = 0.86). CONCLUSION: This variant of the intensity-weighted mean predicts changes in vessel cross-sectional area under conditions of changes in CO2 and cerebral vasospasm. This preliminary study suggests that careful use of this tool may provide accurate evaluation of cerebral blood flow through the large vessels and quantitative changes in diameter, which occur frequently after subarachnoid hemorrhage.
引用
收藏
页码:1076 / 1081
页数:6
相关论文
共 29 条
[1]   MUSICAL MURMURS IN HUMAN CEREBRAL-ARTERIES AFTER SUBARACHNOID HEMORRHAGE [J].
AASLID, R ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1984, 60 (01) :32-36
[2]   ASSESSMENT OF CEREBRAL AUTOREGULATION DYNAMICS FROM SIMULTANEOUS ARTERIAL AND VENOUS TRANSCRANIAL DOPPLER RECORDINGS IN HUMANS [J].
AASLID, R ;
NEWELL, DW ;
STOOSS, R ;
SORTEBERG, W ;
LINDEGAARD, KF .
STROKE, 1991, 22 (09) :1148-1154
[3]   VISUALLY EVOKED DYNAMIC BLOOD-FLOW RESPONSE OF THE HUMAN CEREBRAL-CIRCULATION [J].
AASLID, R .
STROKE, 1987, 18 (04) :771-775
[4]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[5]  
AASLID R, 1984, J NEUROSURG, V42, P81
[6]   INSTANTANEOUS MEASUREMENT OF BLOODFLOW BY ULTRASONIC MEANS [J].
ARTS, MGJ ;
ROEVROS, JMJ .
MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (01) :23-&
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   ABNORMAL CEREBRAL VASODILATION IN ANEURYSMAL SUBARACHNOID HEMORRHAGE - USE OF SERIAL XE-133 CEREBRAL BLOOD-FLOW MEASUREMENT PLUS ACETAZOLAMIDE TO ASSESS CEREBRAL VASOSPASM [J].
DINH, YRT ;
LOT, G ;
BENRABAH, R ;
BAROUDY, O ;
COPHIGNON, J ;
SEYLAZ, J .
JOURNAL OF NEUROSURGERY, 1993, 79 (04) :490-493
[9]   A TRANSCRANIAL DOPPLER STUDY OF BLOOD-FLOW VELOCITY IN THE MIDDLE CEREBRAL-ARTERIES PERFORMED AT REST AND DURING MENTAL ACTIVITIES [J].
DROSTE, DW ;
HARDERS, AG ;
RASTOGI, E .
STROKE, 1989, 20 (08) :1005-1011
[10]   A new method for fixation of probes for transcranial Doppler ultrasound [J].
Giller, CA ;
Giller, AM .
JOURNAL OF NEUROIMAGING, 1997, 7 (02) :103-105