Development of headspace solid-phase microextraction with on-fiber derivatization for determination of hexanal and heptanal in human blood

被引:82
作者
Deng, CH [1 ]
Li, N [1 ]
Zhang, XM [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 813卷 / 1-2期
关键词
headspace solid-phase microextraction; on-fiber derivatization; hexanal; heptanal; blood; lung cancer;
D O I
10.1016/j.jchromb.2004.09.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hexanal and heptanal in human blood have been regarded as potential biomarkers of lung cancer. Owing to their high volatilities and activities, it is difficult to accurately measure the two biomarkers. In the current work, headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization technique was developed for quantitative analysis of hexanal and heptanal in human blood. In the proposed method, the two aldehydes in blood were headspace extracted by using a poly (dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine (PFBHA) at 60degreesC for 8 min. The aldehyde oximes formed on the fiber were desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). The method validations including detection limit, recovery and precision were studied. It was found that the method provided low detection limits of 0.006 nM for hexanal and 0.005 nM for heptanal, recoveries from 89% to 95% and R.S.D. values less than 8.5%. The present method was applied to quantitative analysis of hexanal and heptanal in normal blood and lung cancer blood. Hexanal concentrations from 7.33 to 15.23 muM and heptanal concentrations from 2.47 to 9.23 muM were found in the lung cancer blood, while both hexanal and heptanal in the control blood were lower than 0.6 muM. This further demonstrated that hexanal and heptanal might be the biomarkers of lung cancer. The experimental results showed that GC-MS and HS-SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for determination of in hexanal and heptanal human blood. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 26 条
[1]   Determination of patterns of biologically relevant aldehydes in exhaled breath condensate of healthy subjects by liquid chromatography/atmospheric chemical ionization tandem mass spectrometry [J].
Andreoli, R ;
Manini, P ;
Corradi, M ;
Mutti, A ;
Niessen, WMA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) :637-645
[2]   Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization [J].
Deng, CH ;
Zhang, J ;
Yu, XF ;
Zhang, W ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02) :269-275
[3]   Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry [J].
Deng, CH ;
Zhang, XM ;
Li, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02) :269-277
[4]   Rapid determination of acetone in human plasma by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization [J].
Deng, CH ;
Zhang, W ;
Zhang, J ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02) :235-240
[5]  
ELBELER SE, 1997, J CHROMATOGR B, V702, P211
[6]  
GORDON SM, 1985, CLIN CHEM, V31, P1278
[7]   FREE-RADICALS, ANTIOXIDANTS, AND HUMAN-DISEASE - CURIOSITY, CAUSE, OR CONSEQUENCE [J].
HALLIWELL, B .
LANCET, 1994, 344 (8924) :721-724
[8]   Chemical ionization mass spectrometric determination of acrolein in human breast cancer cells [J].
Kato, S ;
Post, GC ;
Bierbaum, VM ;
Koch, TH .
ANALYTICAL BIOCHEMISTRY, 2002, 305 (02) :251-259
[9]   Formaldehyde in human cancer cells: Detection by preconcentration-chemical ionization mass spectrometry [J].
Kato, S ;
Burke, PJ ;
Koch, TH ;
Bierbaum, VM .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2992-2997
[10]   Field air analysis with SPME device [J].
Koziel, J ;
Jia, MY ;
Khaled, A ;
Noah, J ;
Pawliszyn, J .
ANALYTICA CHIMICA ACTA, 1999, 400 :153-162