Bead injection with a simple flow-injection system: an economical alternative for trace analysis

被引:23
作者
Hartwell, SK [1 ]
Christian, GD
Grudpan, K
机构
[1] Chiang Mai Univ, Dept Chem, Fac Sci, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Dept Chem, Inst Sci & Technol Res & Dev, Chiang Mai 50200, Thailand
[3] Univ Washington, Dept Chem, Seattle, WA 98195 USA
关键词
D O I
10.1016/j.trac.2004.06.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of beads for sample pretreatment, such as preconcentration, isolation, and separation, and for accommodation of chemical reactions has attracted increasing interest. Beads can be used as a removable solid surface in many analytical applications. It is very practical to use beads in a flow-based system, where beads can easily be moved in and out of the system using a flowing stream of reagent(s). This is called the bead-injection (BI) technique, which was first introduced to be used with a sophisticated computer-controlled sequential injection analysis (SIA) system. In many laboratories, a relatively high-cost SIA system is not available, whereas a simple, low-cost, first-generation flow-injection (FI) analysis system is easy to assemble. The development and applications of the BI technique coupled with a lower cost first-generation FI technique is then an alternative. This simple BI-FI system can be a useful tool for pretreatment of samples that are abundant and when there is no need for micro volume control. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:619 / 623
页数:5
相关论文
共 66 条
[1]   Determination of trace iron in beer using flow injection systems with in-valve column and bead injection [J].
Ampan, P ;
Lapanantnoppakhun, S ;
Sooksamiti, P ;
Jakmunee, J ;
Hartwell, SK ;
Jayasvati, S ;
Christian, GD ;
Grudpan, K .
TALANTA, 2002, 58 (06) :1327-1334
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]  
AYORA C, 2002, ANALYST, V127, P1365
[4]   Modification of ISFETs with a monolayer of latex beads for specific detection of proteins [J].
Besselink, GAJ ;
Schasfoort, RBM ;
Bergveld, P .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (09) :1109-1114
[5]   DETERMINATION OF ORGANOLEAD COMPOUNDS BY LIQUID-CHROMATOGRAPHY WITH ONLINE EXTRACTION AND ULTRAVIOLET DETECTION [J].
BUSHEE, DS ;
KRULL, IS ;
SMITH, SB ;
SCHLEICHER, RG .
ANALYTICA CHIMICA ACTA, 1987, 194 :235-245
[6]  
CALLAHAN CA, 1985, BIOL FERT SOILS, V1, P195, DOI 10.1007/BF00257637
[7]   Surface-functionalised nano-beads as novel supports for organic synthesis [J].
Cammidge, AN ;
Downing, S ;
Ngaini, Z .
TETRAHEDRON LETTERS, 2003, 44 (35) :6633-6634
[8]   Label dilution method: a novel tool for bioligand interaction studies using bead injection in the lab-on-valve format [J].
Carroll, AD ;
Scampavia, L ;
Ruzicka, J .
ANALYST, 2002, 127 (09) :1228-1232
[9]   Bead injection ELISA for the determination of antibodies implicated in type 1 diabetes mellitus [J].
Carroll, AD ;
Scampavia, L ;
Luo, D ;
Lernmark, Å ;
Ruzicka, J .
ANALYST, 2003, 128 (09) :1157-1162
[10]   Total nitrogen determination by flow injection using on-line microwave-assisted digestion [J].
Cerda, A ;
Oms, MT ;
Forteza, R ;
Cerda, V .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :273-279