Reliability and validity of Functional Capacity Evaluation methods: a systematic review with reference to Blankenship system, Ergos work simulator, Ergo-Kit and Isernhagen work system

被引:76
作者
Gouttebarge, V [1 ]
Wind, H [1 ]
Kuijer, PPFM [1 ]
Frings-Dresen, MHW [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, AmCOGG Amsterdam Ctr Res Hlth & Hlth Care, Coronel Inst Occupat & Environm Hlth, NL-1100 DE Amsterdam, Netherlands
关键词
Functional Capacity Evaluation; FCE; reliability; validity; systematic review;
D O I
10.1007/s00420-004-0549-7
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: Functional Capacity Evaluation methods (FCE) claim to measure the functional physical ability of a person to perform work-related tasks. The purpose of the present study was to systematically review the literature on the reliability and validity of four FCEs: the Blankenship system (BS), the ERGOS work simulator (EWS), the Ergo-Kit (EK) and the Isernhagen work system (IWS). Methods: A systematic literature search was conducted in five databases (CINAHL, Medline, Embase, OSH-ROM and Picarta) using the following keywords and their synonyms: functional capacity evaluation, reliability and validity. The search strategy was performed for relevance in titles and abstracts, and the databases were limited to literature published between 1980 and April 2004. Two independent reviewers applied the inclusion criteria to select all relevant articles and evaluated the methodological quality of all included articles. Results: The search resulted in 77 potential relevant references but only 12 papers were identified for inclusion and assessed for their methodological quality. The interrater reliability and predictive validity of the IWS were evaluated as good while the procedure used in the intrarater reliability (test-retest) studies was not rigorous enough to allow any conclusion. The concurrent validity of the EWS and EK was not demonstrated while no study was found on their reliability. No study was found on the reliability and validity of the BS. Conclusions: More rigorous studies are needed to demonstrate the reliability and the validity of FCE methods, especially the BS, EWS and EK.
引用
收藏
页码:527 / 537
页数:11
相关论文
共 51 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]  
[Anonymous], 1984, Assessing individuals: Psychological and educational tests and measurements
[3]  
[Anonymous], 2000, Foundations of clinical research: applications to practice
[4]  
[Anonymous], 1978, PSYCHOMETRIC THEORY
[5]  
BLANKENSHIP KL, 1994, BLANKENSHIP SYSTEM F
[6]   Reliability of upper extremity tests measured by the Ergos™ Work Simulator:: A pilot study [J].
Boadella, JM ;
Sluiter, JK ;
Frings-Dresen, MHW .
JOURNAL OF OCCUPATIONAL REHABILITATION, 2003, 13 (04) :219-232
[7]   Test-retest reliability of the Isernhagen Work Systems Functional Capacity Evaluation in patients with chronic low back pain [J].
Brouwer, S ;
Reneman, MF ;
Dijkstra, PU ;
Groothoff, JW ;
Schellekens, JMH ;
Göeken, LNH .
JOURNAL OF OCCUPATIONAL REHABILITATION, 2003, 13 (04) :207-218
[8]  
Carmines EG., 1979, RELIABILITY VALIDITY, DOI DOI 10.4135/9781412985642
[9]   REPRODUCIBILITY AND RESPONSIVENESS OF HEALTH-STATUS MEASURES - STATISTICS AND STRATEGIES FOR EVALUATION [J].
DEYO, RA ;
DIEHR, P ;
PATRICK, DL .
CONTROLLED CLINICAL TRIALS, 1991, 12 (04) :S142-S158
[10]   CONCURRENT VALIDITY OF THE ERGOS WORK SIMULATOR VERSUS CONVENTIONAL FUNCTIONAL-CAPACITY EVALUATION TECHNIQUES IN A WORKERS COMPENSATION POPULATION [J].
DUSIK, LA ;
MENARD, MR ;
COOKE, C ;
FAIRBURN, SM ;
BEACH, GN .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1993, 35 (08) :759-767