A new modeling of loading margin and its sensitivities using rectangular voltage coordinates in voltage stability analysis

被引:12
作者
da Costa, Vander Menengoy [1 ]
Guedes, Magda Rocha [2 ]
de Sousa Rosa, Ariel Lucas [1 ]
Cantarino, Marcelo [3 ]
机构
[1] Univ Fed Juiz de Fora, Dept Elect Engn, BR-36036330 Juiz De Fora, MG, Brazil
[2] Fed Ctr Technol Educ Minas Gerais CEFET, BR-36700000 Leopoldina, MG, Brazil
[3] Centrais Eletr Brasileiras SA ELETROBRAS, BR-20090004 Rio De Janeiro, Brazil
关键词
Electrical Power Systems; Maximum Loading Point; Polar Voltage Coordinates; Rectangular Voltage Coordinates; Sensitivity Analysis; Voltage Stability; 3-PHASE POWER-FLOW; POINT; COLLAPSE; REPRESENTATION; TOOL;
D O I
10.1016/j.ijepes.2009.09.005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents new mathematical models to compute the loading margin, as well as to perform the sensitivity analysis of loading margin with respect to different electric system parameters. The innovative idea consists of evaluating the performance of these methods when the power flow equations are expressed with the voltages in rectangular coordinates. The objective is to establish a comparative process with the conventional models expressed in terms of power flow equations with the voltages in polar coordinates. IEEE test system and a South-Southeastern Brazilian network are used in the simulations. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 22 条
[1]   THE CONTINUATION POWER FLOW - A TOOL FOR STEADY-STATE VOLTAGE STABILITY ANALYSIS [J].
AJJARAPU, V ;
CHRISTY, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :416-423
[2]  
Alves DA, 2000, 2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, P763, DOI 10.1109/ICPST.2000.897118
[3]   POINT OF COLLAPSE METHODS APPLIED TO AC DC POWER-SYSTEMS [J].
CANIZARES, CA ;
ALVARADO, FL ;
DEMARCO, CL ;
DOBSON, I ;
LONG, WF ;
PAL, MK ;
SEMLYEN, A .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (02) :673-683
[4]   POINT OF COLLAPSE AND CONTINUATION METHODS FOR LARGE AC DC SYSTEMS [J].
CANIZARES, CA ;
ALVARADO, FL .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (01) :1-8
[5]  
Cutsem TV, 1998, VOLTAGE STABILITY EL
[6]   Developments in the analysis of unbalanced three-phase power flow solutions [J].
da Costa, Vander Menengoy ;
Lavorato de Oliveira, Marina ;
Guedes, Magda Rocha .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (02) :175-182
[7]   An augmented Newton-Raphson power flow formulation based on current injections [J].
da Costa, VM ;
Pereira, JLR ;
Martins, N .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2001, 23 (04) :305-312
[8]   Developments in the Newton Raphson power flow formulation based on current injections [J].
da Costa, VM ;
Martins, N ;
Pereira, JLR .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (04) :1320-1326
[9]   Simplification, expansion and enhancement of direct interior point algorithm for power system maximum loadability [J].
Dai, YJ ;
McCalley, JD ;
Vittal, V .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (03) :1014-1021
[10]   Augmented rectangular load flow model [J].
Expósito, AG ;
Ramos, ER .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (02) :271-276