Direct stenting

被引:53
作者
Barbato, E
Marco, J
Wijns, W [1 ]
机构
[1] Onze Lieve Vrouwe Ziekenhuis, Ctr Cardiovasc, Aalst, Belgium
[2] Clin Pasteur, Toulouse, France
关键词
direct stenting; PTCA; stent;
D O I
10.1016/S0195-668X(02)00802-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stents have ameliorated the outcome of percutaneous coronary interventions. Improved design, profile and flexibility of the currently available stents now permit to deliver the stent without pre-dilatation. In western European countries, stent implantation now occurs in up to 80% of all percutaneous revascularization procedures. In selected cases the safety and feasibility of direct stenting over conventional balloon-predilatation stenting has been demonstrated, in association with slightly superior outcome. This likely results from reduced vessel watt damage-dissections are seated at the moment they are created-and distal embolization is reduced. In addition, a significant reduction in terms of costs and duration of procedures was demonstrated, white restenosis rate is not reduced with direct stenting. (C) 2003 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:394 / 403
页数:10
相关论文
共 54 条
[41]  
PUEL J, 1987, ARCH MAL COEUR VAISS, V80, P1311
[42]   Endogenous cell seeding - Remnant endothelium after stenting enhances vascular repair [J].
Rogers, C ;
Parikh, S ;
Seifert, P ;
Edelman, ER .
CIRCULATION, 1996, 94 (11) :2909-2914
[43]   Could direct stenting reduce no-reflow in acute coronary syndromes? A randomized pilot study [J].
Sabatier, R ;
Hamon, M ;
Zhao, QM ;
Burzotta, F ;
Lecluse, E ;
Valette, B ;
Grollier, G .
AMERICAN HEART JOURNAL, 2002, 143 (06) :1027-1032
[44]  
Serruys PW, 2000, CIRCULATION, V102, P2930
[45]   A Randomized comparison of the value of additional stenting after optimal balloon Angioplasty for long coronary lesions - Final results of the additional value of NIR Stents for treatment of long coronary lesions (ADVANCE) study [J].
Serruys, PW ;
Foley, DP ;
Suttorp, MJ ;
Rensing, BJWM ;
Suryapranata, H ;
Materne, P ;
van den Bos, A ;
Benit, E ;
Anzuini, A ;
Rutsch, W ;
Legrand, V ;
Dawkins, K ;
Cobaugh, M ;
Bressers, M ;
Backx, B ;
Wijns, W ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :393-399
[46]  
Serruys PW, 1997, CIRCULATION, V96, P3369
[47]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[48]  
SERRUYS PW, 2001, CIRCULATION, V104, P2940
[49]  
Sousa JE, 2001, CIRCULATION, V103, P192
[50]   Direct coronary stenting without balloon or device pretreatment: Acute success and long-term results [J].
Stys, T ;
Lawson, WE ;
Liuzzo, JP ;
Hanif, B ;
Bragg, L ;
Cohn, PF .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (02) :158-163