Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples

被引:217
作者
Varshney, Madhukar
Li, Yanbin [1 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Fayetteville, AR 72701 USA
[2] Univ Arkansas, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
关键词
interdigitated array microelectrode; impedance biosensor; magnetic nanoparticles; bacterial detection; E. coli O157 : H7;
D O I
10.1016/j.bios.2006.08.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1 M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli 0 157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5) CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC = 15.55N-71.04 with R-2=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2408 / 2414
页数:7
相关论文
共 23 条
[1]   Immunoelectrochemical assays for bacteria: Use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella [J].
Brewster, JD ;
Gehring, AG ;
Mazenko, RS ;
VanHouten, LJ ;
Crawford, CJ .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4153-4159
[2]  
*CDCP, 2005, DIS INF
[3]   Strategies for the detection of Escherichia coli O157:H7 in foods [J].
Deisingh, AK ;
Thompson, M .
JOURNAL OF APPLIED MICROBIOLOGY, 2004, 96 (03) :419-429
[4]   RAPID ISOLATION OF ESCHERICHIA-COLI O157-H7 FROM ENRICHMENT CULTURES OF FOODS USING AN IMMUNOMAGNETIC SEPARATION METHOD [J].
FRATAMICO, PM ;
SCHULTZ, FJ ;
BUCHANAN, RL .
FOOD MICROBIOLOGY, 1992, 9 (02) :105-113
[5]   Metal nanoparticles as labels for heterogeneous, chip-based DNA detection [J].
Fritzsche, W ;
Taton, TA .
NANOTECHNOLOGY, 2003, 14 (12) :R63-R73
[6]   Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect salmonella in aqueous solution [J].
Fung, YS ;
Wong, YY .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5302-5309
[7]   Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations [J].
Gawad, S ;
Cheung, K ;
Seger, U ;
Bertsch, A ;
Renaud, P .
LAB ON A CHIP, 2004, 4 (03) :241-251
[8]   Detection of foodborne pathogens using surface plasmon resonance biosensors [J].
Koubová, V ;
Brynda, E ;
Karasová, L ;
Skvor, J ;
Homola, J ;
Dostálek, J ;
Tobiska, P ;
Rosicky, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :100-105
[9]  
Lekowska-Kochaniak Aneta, 2002, Acta Microbiol Pol, V51, P327
[10]  
Liberti PA, 1996, NATO ASI 3 HIGH TECH, V12, P777