Wear debris from two different alumina-on-alumina total hip arthroplasties

被引:47
作者
Böhler, M
Mochida, Y
Bauer, TW
Plenk, H
Salzer, M
机构
[1] Orthoped Hosp Speising VIenna, A-1134 Vienna, Austria
[2] Univ Vienna, Inst Histol & Embryol, Dept Bone & Biomat Res, A-1090 Vienna, Austria
[3] Cleveland Clin Fdn, Dept Anat & Pathol, Cleveland, OH 44195 USA
[4] Herz Jesu Hosp, Dept Orthopaed, A-1030 Vienna, Austria
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2000年 / 82B卷 / 06期
关键词
D O I
10.1302/0301-620X.82B6.9722
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared wear particles from two different designs of total hip arthroplasty with polycrystalline alumina-ceramic bearings of different production periods (group 1, before ISO 6474: group 2, according to ISO 6374). The neocapsules and interfacial connective tissue membranes were retrieved after mean implantation times of 131 months and 38 months, respectively, Specimen blocks were freed from embedding media, either methylmethacrylate or paraffin and digested in concentrated nitric acid. Particles were then counted and their sizes and composition determined by SEM and energy-dispersive x-ray analysis (EDXA), The mean numbers and sizes of most alumina wear particles did not differ for both production periods, but the larger sizes of particle in group 1 point to more severe surface destruction. The increased metal wear in group 2 was apparently due to alumina-induced abrasion of the stems. In this study the concentrations of particles in the periprosthetic tissues were 2 to 22 times lower than those observed previously with polyethylene and alumina/polyethylene wear couples.
引用
收藏
页码:901 / 909
页数:9
相关论文
共 61 条
[1]  
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, P297
[2]  
[Anonymous], CLIN ORTHOP
[3]   LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS [J].
BOEHLER, M ;
KNAHR, K ;
PLENK, H ;
WALTER, A ;
SALZER, M ;
SCHREIBER, V .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :53-59
[4]   THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[5]  
BUECHEL FF, 1994, CLIN ORTHOP RELAT R, P202
[6]  
CLARKE IC, 1992, CLIN ORTHOP RELAT R, V282, P19
[7]   WEAR ANALYSIS OF RETRIEVED ALUMINA HEADS AND SOCKETS OF HIP PROSTHESES [J].
DORLOT, JM ;
CHRISTEL, P ;
MEUNIER, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A3) :299-310
[8]   Polyethylene and titanium alloy particles reduce bone formation - Dose-dependence in bone harvest chamber experiments in rabbits [J].
Goodman, S ;
Aspenberg, P ;
Song, Y ;
Regula, D ;
Lidgren, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (06) :599-605
[9]   Loosening and osteolysis of cemented joint arthroplasties - A biologic spectrum [J].
Goodman, SB ;
Huie, P ;
Song, Y ;
Lee, K ;
Doshi, A ;
Rushdieh, B ;
Woolson, S ;
Maloney, W ;
Schurman, D ;
Sibley, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (337) :149-163
[10]   Cellular profile and cytokine production at prosthetic interfaces - Study of tissues retrieved from revised hip and knee replacements [J].
Goodman, SB ;
Huie, P ;
Song, Y ;
Schurman, D ;
Maloney, W ;
Woolson, S ;
Sibley, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :531-539