System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing system

被引:84
作者
Legget, ME
Leotta, DF
Bolson, EL
McDonald, JA
Martin, RW
Li, XN
Otto, CM
Sheehan, FH [1 ]
机构
[1] Univ Washington, Dept Med, Div Cardiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Anesthesiol, Seattle, WA 98195 USA
[3] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[4] Univ Washington, Dept Stat, Seattle, WA 98195 USA
[5] Green Lane Hosp, Dept Cardiol, Auckland 3, New Zealand
关键词
echocardiography; imaging system; magnetic field; three-dimensional reconstruction;
D O I
10.1109/10.664205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate measurement of left-ventricular (LV) volume and function are important to monitor disease progression and assess prognosis in patients with heart disease. Existing methods of three-dimensional (3-D) imaging of the heart using ultrasound have shown the potential of this modality, but each suffers from inherent restrictions which limit its applicability to the full range of clinical situations. We have developed a technique for image acquisition using a magnetic-field system to track the 3-D echocardiographic imaging planes and 3-D image analysis software including the piecewise smooth subdivision method for surface reconstruction. The technique offers several advantages over existing methods of 3-D echocardiography. The results of validation using in vitro LV's show that the technique allows accurate measurement of LV volume and anatomically accurate 3-D reconstruction of LV shape and is, therefore, suitable for analysis of regional as well as global function.
引用
收藏
页码:494 / 504
页数:11
相关论文
共 32 条
  • [1] Aakhus S, 1994, J Am Soc Echocardiogr, V7, P571
  • [2] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [3] BOLSON EL, 1995, P IEEE COMPUTERS CAR, P63
  • [4] DEROSE T, 1992, SPIE, V1830, P212
  • [5] 3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION
    DETMER, PR
    BASHEIN, G
    HODGES, T
    BEACH, KW
    FILER, EP
    BURNS, DH
    STRANDNESS, DE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) : 923 - 936
  • [6] FILER EP, 1994, THESIS U WASHINGTON
  • [7] A MECHANICAL ARM FOR SPATIAL REGISTRATION OF TWO-DIMENSIONAL ECHOCARDIOGRAPHIC SECTIONS
    GEISER, EA
    CHRISTIE, LG
    CONETTA, DA
    CONTI, CR
    GOSSMAN, GS
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (01): : 89 - 101
  • [8] 3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD
    GHOSH, A
    NANDA, NC
    MAURER, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) : 655 - 661
  • [9] 3-DIMENSIONAL ECHOCARDIOGRAPHY - IN-VITRO AND IN-VIVO VALIDATION OF LEFT-VENTRICULAR MASS AND COMPARISON WITH CONVENTIONAL ECHOCARDIOGRAPHIC METHODS
    GOPAL, AS
    KELLER, AM
    SHEN, ZQ
    SAPIN, PM
    SCHROEDER, KM
    KING, DL
    KING, DL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) : 504 - 513
  • [10] HATANGADI RB, 1994, THESIS U WASHINGTON