Characterization of and correction for eddy current artifacts in echo planar diffusion imaging

被引:266
作者
Jezzard, P
Barnett, AS
Pierpaoli, C
机构
[1] NIMH, Unit MRI Phys, Lab Brain & Cognit, NIH, Bethesda, MD 20892 USA
[2] NINDS, Neuroimaging Branch, NIH, Bethesda, MD 20892 USA
关键词
diffusion MRI; interleaved EPI; artifacts; eddy currents; navigator echoes;
D O I
10.1002/mrm.1910390518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance diffusion imaging is potentially an important tool for the noninvasive characterization of normal and pathological tissue. The technique, however, is prone to a number of artifacts that can severely affect its ability to provide clinically useful information. In this study, the problem of eddy current-induced geometric distortions that occur in diffusion images acquired with echo planar sequences was addressed. These geometric distortions produce artifacts in computed maps of diffusion parameters and are caused by misalignments in the individual diffusion-weighted images that comprise the diffusion data set. A new approach is presented to characterize and calibrate the eddy current effects, enabling the eddy current distortions to be corrected in sets of interleaved (or snapshot) echo planar diffusion images. Correction is achieved by acquiring one-dimensional field maps in the read and phase encode direction for each slice and each diffusion step. The method is then demonstrated through the correction of distortions in diffusion images of the human brain. It is shown that by using the eddy current correction scheme outlined, the eddy current-induced artifacts in the diffusion-weighted images are almost completely eliminated. In addition, there is a significant improvement in the quality of the resulting diffusion tensor maps.
引用
收藏
页码:801 / 812
页数:12
相关论文
共 34 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]  
ASATO R, 1992, P SMRM 11 ANN M BERL, P1226
[3]  
BARNETT AS, 1997, P ISMRM 5 ANN M VANC, P1726
[4]  
BARNETT AS, 1997, P ISMRM 5 ANN M VANC, P1727
[5]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[6]  
BASSER PJ, 1995, P SMR 3 ANN M NIC, P308
[7]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
[8]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770
[9]   INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
THOMPSON, RM ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :67-72
[10]   MR DIFFUSION IMAGING OF THE HUMAN BRAIN [J].
CHIEN, D ;
BUXTON, RB ;
KWONG, KK ;
BRADY, TJ ;
ROSEN, BR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) :514-520