Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids

被引:115
作者
Choi, MG
Camilleri, M
Burton, DD
Zinsmeister, AR
Forstrom, LA
Nair, KS
机构
[1] Mayo Clin & Mayo Fdn, Gastroenterol Res Unit, Biostat Sect, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Gastroenterol Res Unit, Nucl Med Sect, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Mass Spectrometry Core Lab, Rochester, MN 55905 USA
关键词
D O I
10.1111/j.1572-0241.1998.092_c.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective: The accuracy of the C-13-octanoic acid breath test is enhanced bk breath sampling over 6 h rather than 4 h, but this increases the cost of the test. Our ain was to validate a less costly but accurate sequence of breath sampling for measuring gastric emptying of solids. Methods: We performance the C-13-octanoic acid breath test and tested its reproducibility relative to simultaneous scintigraphy in 30 healthy volunteers. Hit stilts: There was a significant but weak correlation between t(1/2) measured by the two tests (r(s) = 0.54, p < 0.005), but not between the duration of the lag phase. The differences in the t(1/2) measurements between the tests were different between subjects but were highly reproducible within subjects, Within- and between-subject variations of measurements of gastric emptying with the C-13-octanoic acid breath test were not significantly different from the variations observed with scintigraphy. A subset of 11 breath samples collected over 6 h (24 samples) predicted (r(2) > 0.95) the variables characterizing the cumulative appearance of (CO2)-C-13 in breath; these samples were at 35, 30, 95, 110, 140, 155, 215, 245, 260, 290, and 335 min, The accuracy of this subset of sampling times was confirmed in a separate set of breath test samples over 6 h from the same 30 subjects, Conclusions: The C-13-octanoic acid breath test for gastric emptying of solids is as reproducible as scintigraphy. A subset of 11 sampling times provides sufficient information to characterize the whole breath-test curve, but the sampling period should be extended to 6 h after dosing. (C) 1998 by Am. Coll. of Gastroenterology.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 19 条
[11]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[12]  
JONES R, 1992, BRIT J CLIN PRACT, V46, P95
[13]   ISOTOPE-SELECTIVE NONDISPERSIVE INFRARED SPECTROMETRY FOR DETECTION OF HELICOBACTER-PYLORI INFECTION WITH C-13-UREA BREATH TEST [J].
KOLETZKO, S ;
HAISCH, M ;
SEEBOTH, I ;
BRADEN, B ;
HENGELS, K ;
KOLETZKO, B ;
HERING, P .
LANCET, 1995, 345 (8955) :961-962
[14]  
MEYER JH, 1983, J NUCL MED, V24, P197
[15]  
MOORE JG, 1985, J NUCL MED, V26, P1206
[16]  
*SAS I INC, 1989, SAS STAT US GUID VER, V2, P1135
[17]  
STEPHEN AM, 1983, GASTROENTEROLOGY, V85, P589
[18]  
TALLEY NJ, 1992, GASTROENTEROLOGY, V102, P1259
[19]  
TOTHILL P, 1978, J NUCL MED, V19, P256