Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion

被引:428
作者
Rampersaud, YR
Foley, KT
Shen, AC
Williams, S
Solomito, M
机构
[1] Image Guided Surg Res Ctr, Memphis, TN 38104 USA
[2] Univ Toronto, Div Orthopaed Surg, Toronto, ON, Canada
[3] Univ Tennessee, Dept Neurosurg, Memphis, TN USA
[4] Methodist HealthCare, Dept Radiat Therapy, Memphis, TN USA
关键词
bone screws; fluoroscopy; ionization; lumbar vertebrae; occupational exposure; radiation;
D O I
10.1097/00007632-200010150-00016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro study to determine occupational radiation exposure during lumbar fluoroscopy. Objectives. To assess radiation exposure to the spine surgeon during fluoroscopically assisted thoracolumbar pedicle screw placement. Summary of Background Data. Occupational radiation exposure during a variety of fluoroscopically assisted musculoskeletal procedures has been previously evaluated. No prior study has assessed fluoroscopy-related radiation exposure to the spine surgeon. Methods. Bilateral pedicle screw placement (T11-S1) was performed in six cadavers using lateral fluoroscopic imaging. Radiation dose rates to the surgeon's neck, torso, and dominant hand were measured with dosimeter badges and thermolucent dosimeter (TLD) rings. Radiation levels were also quantified at various distances from the dorsal lumbar surface using an ion chamber radiation survey meter. Results. The mean dose rate to the neck was 8.3 mrem/min. The dose rate to the torso was greatest when the surgeon was positioned ipsilateral to the beam source (53.3 mrem/min, compared with 2.2 mrem/min on the contralateral side). The average hand dose rate was 58.2 mrem/min. A significant increase in hand dose rate was associated with placement of screws ipsilateral to the beam source (P = 0.0005) and larger specimens (P = 0.0007). Radiation levels significantly decreased as distance from the beam source and dorsal body surface increased. The greatest levels of radiation were noted on the side where the primary radiograph beam entered the cadaver. Conclusion. Fluoroscopically assisted thoracolumbar pedicle screw placement exposes the spine surgeon to significantly greater radiation levels than other, nonspinal musculoskeletal procedures that involve the use of a fluoroscope. In fact, dose rates are up to 10-12 times greater. Spine surgeons performing fluoroscopically assisted thoracolumbar procedures should monitor their annual radiation exposure. Measures to reduce radiation exposure and surgeon awareness of high-exposure body and hand positions are certainly called for.
引用
收藏
页码:2637 / 2645
页数:9
相关论文
共 33 条
  • [1] BARRY TP, 1984, CLIN ORTHOP RELAT R, P160
  • [2] BREAST-CANCER AMONG RADIOLOGIC TECHNOLOGISTS
    BOICE, JD
    MANDEL, JS
    DOODY, MM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (05): : 394 - 401
  • [3] RADIATION EXPOSURE TO ANGIOGRAPHERS UNDER DIFFERENT FLUOROSCOPIC IMAGING CONDITIONS
    BOONE, JM
    LEVIN, DC
    [J]. RADIOLOGY, 1991, 180 (03) : 861 - 865
  • [4] A SURVEY OF FLUOROSCOPIC EXPOSURE RATES - AAPM TASK GROUP NO 11 REPORT
    BOONE, JM
    PFEIFFER, DE
    STRAUSS, KJ
    ROSSI, RP
    LIN, PJP
    SHEPARD, JS
    CONWAY, BJ
    [J]. MEDICAL PHYSICS, 1993, 20 (03) : 789 - 794
  • [5] REDUCTION OF RADIATION EXPOSURE WHILE MAINTAINING HIGH-QUALITY FLUOROSCOPIC IMAGES DURING INTERVENTIONAL CARDIOLOGY USING NOVEL X-RAY TUBE TECHNOLOGY WITH EXTRA BEAM FILTERING
    DENBOER, A
    DEFEYTER, PJ
    HUMMEL, WA
    KEANE, D
    ROELANDT, JRTC
    [J]. CIRCULATION, 1994, 89 (06) : 2710 - 2714
  • [6] AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT
    FAULKNER, K
    MOORES, BM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) : 272 - 276
  • [7] Finkelstein MM, 1998, CAN J CARDIOL, V14, P1385
  • [8] IRRADIATION OF THE SURGEON DURING PINNING OF FEMORAL FRACTURES
    GIACHINO, AA
    CHENG, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (02): : 227 - 229
  • [9] Ionising radiation during internal fixation of extracapsular neck of femur fractures
    Giannoudis, PV
    McGuigan, J
    Shaw, DL
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06): : 469 - 472
  • [10] Radiation risk to the urologist during endourologic procedures, and a new shield that reduces exposure
    Giblin, JG
    Rubenstein, J
    Taylor, A
    Pahira, J